Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: K&A RESTORATION SERVICES

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of K&A RESTORATION SERVICES in 520 SUBROOK MANOR DRIVE, DUNCANSVILLE, PA 16635 (NAICS 236118). OSHA activity number 341902971.

Watch K&A Restoration Services — free Get an email when a new federal OSHA severe-injury report for K&A Restoration Services is published. One employer, no account, unsubscribe in one click.
Site address
520 SUBROOK MANOR DRIVE
City
DUNCANSVILLE
State
PA
ZIP
16635
Mailing
2309 UNION AVENUE, ALTOONA, PA 16602
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236118
Employees
8
Ownership type
A

8 citations on file for this inspection.

1910.132 A

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3207.00 · Current $2100.00 Reduced
29 CFR 1910.132(a): Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered:    a)  At the jobsite, on or about November 10, 2016 - Employees were not provide adequate splash goggles when handling MMR Mold Stain Remover containing Sodium Hyperchlorite, a corrosive.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3207

1910.134 C01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1604.00 · Current $500.00 Reduced
29 CFR 1910.134(c)(1): The employer did not establish and implement a written respiratory protection program, including worksite specific procedures and all applicable provisions of this section, in the workplace where respirators were required by the employer as necessary to protect the health of the employee:    At the jobsite, on or about November 10, 2016 - A written respiratory protection was not established and implemented when employees were required to wear respirators.  Employees are required to wear respirators when conducting mold remediation operations.
Recent events (2)
  • — I (S) $500
  • — Z (S) $1604

1910.134 E01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator before the employee was fit tested or required to use the respirator in the workplace:  a)  At the jobsite, on or about November 10, 2016 - Employees were not provided with a medical evaluation prior to the required use of a respirator in the workplace.  Employees are required to wear respirators when conducting mold remediation operators.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 F01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(f)(1): The employer did not ensure that employees using a tight-fitting facepiece respirator pass an appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT) as stated in this paragraph:     a)  At the jobsite, on or about November 10, 2016 - Employees using a tight-fitting facepeice respirator were not provided with a fit test prior to the required use of a respirator.  Employees are required to wear a respirator when conducting mold remediation operations.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 K01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(k)(1): The employer did not provide effective training to ensure that each employee could demonstrate knowledge of 1910.134(k)(1)(i) - (vii):  a)  At the jobsite, on or about November 10, 2016 - Employees were not provided effective respiratory protection training.  Employees are required to wear a respirator when conducting mold remediation operations.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.151 C

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3207.00 · Current $2100.00 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:    a) At the jobsite, on or about November 10, 2016 - Employees were not provided with suitable facilities for quick drenching or flushing of the eyes within the work area for immediate emergency use.  Employees use MMR Mold Stain Remover containing sodium hypochlorite, a corrosive, when conducting mold remediation operations.
Recent events (2)
  • — I (S) $2100
  • — Z (S) $3207

1910.1200 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3207.00 · Current $1800.00 Reduced
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:    a)  At the jobsite, on or about November 10, 2016 - A written hazard communication program was not developed and implemented at the workplace.  Employees use MMR Mold Stain Remover containing sodium hypochlorite, a corrosive, when conducting mold remediation operations.
Recent events (2)
  • — I (S) $1800
  • — Z (S) $3207

1910.1200 H01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:  a)  At the jobsite on or about November 10, 2016 - Employees were not provided with effective information and training on hazardous chemicals in their work area at the time of their initial assignment.  Employees use MMR Mold Stain Remover containing Sodium Hyperchlorite, a corrosive, when conducting mold remediation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341902971.