PHILADELPHIA, PA —
OSHA Inspection: PHILADELPHIA METAL AND RESOURCE RECOVERY, INC.
Programmed Related inspection · Health discipline
At a glance
On , OSHA opened a programmed Related health inspection of PHILADELPHIA METAL AND RESOURCE RECOVERY, INC. in 542 NORTH PERCY STREET, PHILADELPHIA, PA 19123 (NAICS 423930). OSHA activity number 341907301.
Where did this inspection happen?
- Establishment
- PHILADELPHIA METAL AND RESOURCE RECOVERY, INC.
- Site address
- 542 NORTH PERCY STREET
- City
- PHILADELPHIA
- State
- PA
- ZIP
- 19123
- Mailing
- 2204 EAST SOMERSET STREET, PHILADELPHIA, PA 19134
What kind of inspection was it?
- Inspection type
- Programmed Related (J)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423930
- Employees
- 1
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.1025 L01 I
- Issued
- Abate by
- Penalty
- Initial $8873.00 · Current $5324.00 Reduced
1591
General-duty citation text
29 CFR 1910.1025(l)(1)(i): Employee(s) working in an area where there is potential exposure to airborne lead at any level were not informed of the content of Appendices A and B of 29 CFR 1910.1025: a. The Gun Range LLC, 542 North Percy Street, Philadelphia, PA 19123 - The employer did not provide employees with information and training about the specific hazards associated with lead. Observed On or About 11/21/16
Recent events (2)
- — I (S) $5323.8
- — Z (S) $8873
1910.1025 N01 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
1591
General-duty citation text
29 CFR 1910.1025(n)(1)(i): Records of all monitoring for lead exposure as required in 29CFR 1910.1025(d), were not established and/or accurately maintained: a. The Gun Range LLC, 542 North Percy Street, Philadelphia, PA 19123 - The employer did not maintain records of all air-monitoring for lead exposure. Observed On or About 11/21/16
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1025 N02 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
1591
General-duty citation text
29 CFR 1910.1025(n)(2)(i): Records of medical surveillance for lead exposure required by 29 CFR 1910.1025(j), were not established and/or accurately maintained for each employee subject to medical surveillance:(a)(IDENTIFY SPECIFICS AND/OR LOCATION(S)) a. The Gun Range LLC, 542 North Percy Street, Philadelphia, PA 19123 - The employer did not maintain records of the employee biological monitoring, including blood sampling and analysis for lead and zinc protoporphyrin levels. Observed On or About 11/21/16
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 C01
- Issued
- Abate by
- Penalty
- Initial $8873.00 · Current $5324.00 Reduced
1591
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a. The Gun Range LLC, 542 North Percy Street, Philadelphia, PA 19123 - The employer did not establish and implement a written respiratory protection program with worksite-specific procedures, where employees were required to wear North Safety 770030 Medium 7700 Series Half Mask air-purifying respirators. These employees used shoves to pick-up spent lead bullets. Observed On or About 11/21/16
Recent events (2)
- — I (S) $5323.8
- — Z (S) $8873
1910.134 F02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
1591
General-duty citation text
29 CFR 1910.134(f)(2): Employee(s) using tight-fitting facepiece respirators were not fit tested prior to initial use of the respirator: a. The Gun Range LLC, 542 North Percy Street, Philadelphia, PA 19123 - The employer did not provide employees, who were required to wear North Safety 770030 Medium 7700 Series Half Mask air-purifying respirators, with respirator fit-testing. These employees removed spent lead bullets and materials covered with lead dust from an indoor gun range. Observed On or About 11/21/16
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1025 F02 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
1591
General-duty citation text
29 CFR 1910.1025(f)(2)(i): The employer did not implement a respiratory protection program in accordance with 29 CFR 1910.134(b) through (d) (except (d)(1)(iii)), and (f) through (m) for each employee required by 29 CFR 1910.1025 to use a respirator: a. The Gun Range LLC, 542 North Percy Street, Philadelphia, PA 19123 - The employer did not provide employees, who wore North Safety 770030 Medium 7700 Series Half Mask air-purifying respirators and used shoves to pick-up spent lead bullets, with respirator fit-testing. Observed On or About 11/21/16
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 423930)
OGDEN, UT—2026-07-10
TEAR A PART AUTO RECYCLING
GARNER, NC—2026-07-09
161490 - CAROLINA METAL RECYCLERS, LLC
JOPLIN, MO—2026-07-07
SERVICE RECYCLING - NORTH PLANT
HOLBROOK, NY—2026-07-01
ARROW SCRAP CORPORATION
DOVER, OH—2026-07-01
SPEEDIE AUTO SALVAGE
More inspections in PA
MILTON, PA—2026-07-10
HOMETOWN FOODS CHEF BOYARDEE CO.
SUNBURY, PA—2026-07-10
DEMPSEY UNIFORM & LINEN SUPPLY, INC
LANDISVILLE, PA—2026-07-10
FAIRVIEW DEMOLITION LLC
YORK, PA—2026-07-10
AMERICAN SPECIALTY SYSTEMS INC.
WILLIAMSPORT, PA—2026-07-10
INTERNATIONAL PAINT PROS
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341907301.