OSHA Inspection: PRECISION SPECIALTY FASTENER INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of PRECISION SPECIALTY FASTENER INC. in 555 CANNELTON ROAD, DARLINGTON, PA 16115 (NAICS 332722). OSHA activity number 341911865.

Watch Precision Specialty Fastener INC. — free Get an email when a new federal OSHA severe-injury report for Precision Specialty Fastener INC. is published. One employer, no account, unsubscribe in one click.
Site address
555 CANNELTON ROAD
City
DARLINGTON
State
PA
ZIP
16115
Mailing
555 CANNELTON ROAD, DARLINGTON, PA 16115
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332722
Employees
18
Ownership type
A

2 citations on file for this inspection.

1904.29 B03

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1904.29(b)(3): The employer did not enter each recordable injury or illness on the OSHA 300 Log and 301 Incident Report within seven (7) calendar days of receiving information that a recordable injury or illness had occurred:  a)  In the Facility, on or about November 9, 2016 - The employer did not record an occupational injury on the OSHA 300 log within seven calendar days of the injury.  A restricted injury case occurred at the facility on August 15, 2016 and it was not recorded on the 2016 OSHA 300 log as of November 9, 2016.
Recent events (1)
  • — Z (O) $0

1910.147 C06 I

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirement of this standard were being followed:  a)  In the Facility, on or about November 9, 2016 - The employer did not conduct a annual inspection of the company's energy control procedures to ensure the requirements of the lockout standard were being followed.