BROWNSVILLE, TX —
OSHA Inspection: PEREZ BROTHERS MILLWRIGHTS
Unprogrammed Related inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Related safety inspection of PEREZ BROTHERS MILLWRIGHTS in 9155 RL OSTOS RD, BROWNSVILLE, TX 78520 (NAICS 238290). OSHA activity number 341925246.
Where did this inspection happen?
- Establishment
- PEREZ BROTHERS MILLWRIGHTS
- Site address
- 9155 RL OSTOS RD
- City
- BROWNSVILLE
- State
- TX
- ZIP
- 78520
- Mailing
- 1100 SOUTH 5TH STREET, SLATON, TX 79364
What kind of inspection was it?
- Inspection type
- Unprogrammed Related (G)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238290
- Employees
- 8
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.300 B01
- Issued
- Abate by
- Penalty
- Initial $2897.00 · Current $1500.00 Reduced
General-duty citation text
29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use: On or about November 16, 2016, and at time prior thereto, at this construction work site, the employees were repairing different welded metal parts, and using unguarded portable grinders: a. 5" Angle Grinder; and, b. 7"/180 mm Heavy Duty Angle Grinder.
Recent events (2)
- — I (S) $1500
- — Z (S) $2897
1926.351 B01
- Issued
- Abate by
- Penalty
- Initial $2897.00 · Current $1500.00 Reduced
General-duty citation text
29 CFR 1926.351(b)(1): Arc welding or cutting cable(s) were not of the completely insulated, flexible type, capable of handling the maximum current requirements of the work in progress: On or about November 16, 2016, and times prior thereto, at this establishment, employees used arc welding equipment with exposed electrode cables.
Recent events (2)
- — I (S) $1500
- — Z (S) $2897
1926.405 G02 III
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.405(g)(2)(iii): Flexible cords were not used in continuous lengths without splice or tap: On or about November 16, 2016, and times prior thereto, at this establishment, employees used equipment that had improperly repaired plugs on flexible electrical cords: a. An extension flexible cord used with portable grinders; and, b. An extension flexible cord connected to a arc welding and cutting machine.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.1053 B15
- Issued
- Abate by
- Penalty
- Initial $2897.00 · Current $2000.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(15): Ladders were not inspected by a competent person for visible defects on a periodic basis and after an occurrence that could affect their safe use: On or about November 16, 2016, and times prior thereto, at this construction site, employees were working on a broken ladder with visible defects which has not been inspected by a competent person prior to use.
Recent events (2)
- — I (S) $2000
- — Z (S) $2897
1926.1053 B16
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(16): Portable ladders with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately marked in a manner that readily identifies them as defective, or tagged with "Do Not Use" or similar language, and were not withdrawn from service until repaired: On or about November 16, 2016, and times prior thereto, at this construction site, employees were working on a broken ladder with visible defects which has not been taken out of service until repaired or replaced.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 238290)
PRESTONSBURG, KY—2026-06-23
69242 - R - H CONTRACTING LLC
FONTANA, CA—2026-06-18
MOBILE MEDICAL TECHNOLOGIES
LE ROY, NY—2026-06-17
CHUCK MCLAUGHLIN LLC
AURORA, IL—2026-06-10
PEPPER CONSTRUCTION
SALT LAKE CITY, UT—2026-06-04
SOLID CONSTRUCTION GROUP LLC
More inspections in TX
SPRING, TX—2026-07-10
DORSTENER WIRE TECH INC.
FORT WORTH, TX—2026-07-10
RC PROFESSIONAL ROOFING OF TEXAS LLC
CYPRESS, TX—2026-07-10
FEDERICO CARVAJAL GARCIA
SAN ANTONIO, TX—2026-07-10
ED LONG'S METAL WORKS
SAN ANTONIO, TX—2026-07-09
WAREHOUSE RACK COMPANY, LP
Source