Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: TRAVEL RAMP, INC.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of TRAVEL RAMP, INC. in 1360 W. UNIVERSITY AVE., GAINESVILLE, FL 32601 (NAICS 238990). OSHA activity number 341927317.

Watch Travel Ramp, INC. — free Get an email when a new federal OSHA severe-injury report for Travel Ramp, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
TRAVEL RAMP, INC.
Site address
1360 W. UNIVERSITY AVE.
City
GAINESVILLE
State
FL
ZIP
32601
Mailing
P.O. BOX 2015, ALACHUA, FL 32616
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238990
Employees
6
Ownership type
A

1 citation on file for this inspection.

1926.351 B04

Serious Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $3803.00 · Current $2282.00 Reduced
29 CFR 1926.351(b)(4): Welding cable(s) in use were in need of repair:  a.   On November 17, 2016 in stairwell 5 of The Standard apartment project in Gainesville, the welding cables used with the Miller Suitcase X-Treme 12VS welding machine were in need of repair with bare metal conductor exposed and damaged and cracking rubber insulation, exposing the welding employee to an electric shock hazard.
Recent events (2)
  • — I (S) $2281.8
  • — Z (S) $3803