Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: BAY WELDING SERVICES, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BAY WELDING SERVICES, INC. in 3301 EAST END ROAD, HOMER, AK 99603 (NAICS 336612). OSHA activity number 341946853.

Watch BAY Welding Services, INC. — free Get an email when a new federal OSHA severe-injury report for BAY Welding Services, INC. is published. One employer, no account, unsubscribe in one click.
Site address
3301 EAST END ROAD
City
HOMER
State
AK
ZIP
99603
Mailing
PO BOX 534, HOMER, AK 99603
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336612
Employees
24
Ownership type
A

16 citations on file for this inspection.

1910.23 D01 I

Serious Gravity 5 2 instances 22 exposed
Issued
Abate by
Penalty
Initial $3029.00 · Current $1515.00 Reduced
29 CFR 1910.23(d)(1)(i): Flight(s) of stairs with four or more risers, less than 44 inches wide and having both sides enclosed, were not equipped with at least one standard handrail.  South shop and south bay cutting areas; on or about 29 November 2016 and times prior thereto; two instances were noted where stairways did not have handrails installed:       a. South shop, stairway leading to the upstairs vinyl cutting area; a stairway measuring approximately 34-inches in width with 13 vertical risers did not have a handrail installed on either side.        b. South bay, stairway measuring less than 44-inches in width with five vertical risers did not handrail installed on either side.  This condition exposed employees to a fall hazard.
Recent events (2)
  • — I (S) $1514.5
  • — Z (S) $3029

1910.23 D01 IV

Serious Gravity 1 1 instance 22 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.23(d)(1)(iv): Flights of stairs with 4 or more risers, more than 44 inches wide but less than 88 inches wide, were not equipped with on standard handrail on each enclosed side.    South bay, cutting area; on or about 29 November 2016 and times prior thereto; a stairway measuring approximately 50-inches in width with five vertical risers was not equipped with a standard handrail on either side. This condition exposed employees to a fall hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 1 2 instances 22 exposed
Issued
Abate by
Penalty
Initial $1817.00 · Current $909.00 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks.  South bay; on or about 29 November 2016 and times prior thereto; two instances were noted where mechanical machines did not have barrier guards installed:        a. An Accurpress Press Brake; model 713012, serial number 6922, did not have a barrier guard installed to prevent access behind the machine during operations. Miscellaneous items were stored behind the machine.       b. An Accurshear Shear; model 613512, serial number unknown, did not have a barrier guard to prevent access behind the machine during operation. Miscellaneous items store behind the machine.   This condition exposed employees to a struck by hazard
Recent events (2)
  • — I (S) $908.5
  • — Z (S) $1817

1910.212 B

Serious Gravity 1 2 instances 22 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving.  West bay and machine shop; on or about 29 November 2016 and times prior thereto; two instances were noted where machinery was not securely anchored to prevent movement:       a. West bay, welding area; a Delta 8-inch Bench Grinder, Model 23-725, serial number 00052, was not securely anchored to prevent movement.        b. Machine shop; a Jet 20-inch Floor Drill Press, Model J-2550; serial number 14092001 was not securely anchored to prevent movement.   This condition exposed employees to a struck by hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.213 D01

Serious Gravity 5 1 instance 22 exposed
Issued
Abate by
Penalty
Initial $2423.00 · Current $1212.00 Reduced
29 CFR 1910.213(d)(1): Circular handfed crosscut table saw(s) were not guarded by an automatically adjusting hood which completely enclosed that portion of the saw above the table and above the material being cut.  South bay; on or about 29 November 2016 and times prior thereto; A Delta 10-inch Table Saw, category number 34-761S, serial number 83000743 was missing the protective blade guard. This condition exposed employees to a caught in hazard.
Recent events (2)
  • — I (S) $1211.5
  • — Z (S) $2423

1910.215 B09

Serious Gravity 1 2 instances 22 exposed
Issued
Abate by
Penalty
Initial $1817.00 · Current $909.00 Reduced
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch.  West bay, welding bench area; on or about 29 November 2016 and times prior thereto; two instances were noted where the tongue guards were missing on bench grinders:       a. A Delta 8-inch Bench Grinder, Model 23-725, serial number 00052; the tongue guards on the left and right hand sides were removed.        b. A Milwaukee 8-inch Bench Grinder, Model K56Y, serial number 604477SM815, the tongue guards on the left and right hand sides were removed.  This condition exposed employees to a struck by hazard.
Recent events (2)
  • — I (S) $908.5
  • — Z (S) $1817

1910.303 B02

Serious Gravity 5 1 instance 22 exposed
Issued
Abate by
Penalty
Initial $3029.00 · Current $1515.00 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling.  Machine shop, interior wall; on or about 29 November 2016 and times prior thereto; an energized two-place electrical outlet box had an Ace six-way receptacle splitter attached to a 25-foot orange heavy duty extension cord, which is  routed to a three foot, six-place wall mounted relocatable power tap; Ace model number 33543. The relocatable power tap is used to distributed power to five Makita model DC18RA, 3.0 Amp battery charging stations. A 25-foot orange extension cord attached to the relocatable power tap is used to provide power to a three receptacle splitter, which is used to provide power to three additional Makita model DC1414, 2.6 amp battery charging stations. This condition exposed employees to a fire hazard.
Recent events (2)
  • — I (S) $1514.5
  • — Z (S) $3029

1910.303 G01 II

Serious Gravity 1 2 instances 22 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage.  South and Machine shop bays; on or about 29 November 2016 and times prior thereto; two instances were noted where electrical panels had items stored in front of the panel impeding immediate access.       a. South bay, cutting area; several pieces of aluminum remnants were stored in front of the Siemens Main Breaker Panel impeding access.       b. Machine shop, interior wall; a DP-100 press and various items were stored in front of the Challenger Main Breaker Panel impeding access.   This condition exposed employees to electrical shock and fire hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 5 21 instances 22 exposed
Issued
Abate by
Penalty
Initial $3634.00 · Current $1817.00 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed.  Throughout the shop bay areas; on or about 29 November 2016 and times prior thereto; the employer did not ensure that electrical openings were effectively closed. 21 instances were noted:       a. South bay, tool area; an energized four-place electrical outlet box had a knockout plug missing on the left hand side.       b. South bay, entrance area; an energized two-place light switch had a knockout plug missing on the left hand side.       c. South bay, cutting area, interior wall; an energized electrical box had two knockout plugs missing on the right hand side and on the left hand side.       d. South bay, interior wall; an energized Siemens G4040B1200, Type 1, 40-place Main Breaker Panel was missing a knockout plug on the upper left hand side.       e. South bay; interior wall, to the left and adjacent to a Siemens Main Breaker Panel; an energized electrical box had a knockout plug missing on the top of the box.       f. South bay, cutting area, below the Siemens switch box; an energized 220-volt outlet was missing knockout out plugs on the left and right hand sides, and on the top.       g. South bay, cutting area; an energized Siemens G2442L3200CU, Type 1, 24-place Main Breaker Panel had two knockout plates, measuring approximately 1-inch by 2 and 1/4 inches, on spaces 8 and 10 removed and covered with silver duct tape.       h. South bay, cutting area, above the Siemens Main Breaker Panel; an energized four-place electrical outlet box was missing a knockout plug on the left hand side.       i. South bay, above door adjacent to the cutting area; two knockout plugs were missing from the bottom of an energized electrical box.       j. West bay, adjacent to the entry way; an energized Siemens G1224ML1125, Type 1,  12-place Main Breaker Panel had two knockout plates, measuring approximately 1-inch by 2 and 1/4  inches on, spaces 9 and 11 removed and covered with blue duct tape.       k. West bay, adjacent to the entry way and to the left of the Siemens Main Breaker Panel; an energized single place light switch was missing a knockout plug on the right hand side.       l. West bay, south wall; an energized two-place electrical outlet box, with a number four printed on the right hand side, was missing a knockout plug on the right hand side.       m. West bay, to the left of the Challenger Main Breaker Panel; an energized two-place electrical outlet was missing a knockout plug on the left hand side.        n. Machine shop, adjacent to the passage way; an energized Siemens P4260B1225CU, Type 1, 42-place Main Breaker Panel had a knockout plate, measuring approximately 1-inch by 2 and 1/4 inches missing on space number 30.       o. Machine shop, just above and to the left of the Siemens Main Breaker Panel; an energized electrical box was missing the cover plate. Outlet box located approximately seven feet from the lower surface.       p. Machine shop, exterior door entrance, adjacent to roll-up door; an energized light switch was missing a knockout plug on the top of the outlet box.       q. East bay, adjacent to entryway to the machine shop; an energized Challenger SL20, Type 1, 40-place Main Breaker Panel was missing a knockout plug on the lower right hand side.       r. East bay, adjacent to the exit; an energized two-place electrical switch was missing the rocker switch on the right hand side. Opening was covered with duct tape.       s. East bay, interior wall; and energize outlet with RSP printed on left hand side was missing a knockout plug on the left hand side.       t. Wood shop to the left of the doorway; an energized 240-volt outlet was missing a knockout plug on the right hand side.       u. South Shop, adjacent to air compressor; an energized electrical outlet box was missing the cover plate.    This condition exposed employees to an electrical shock and electrical burn hazards.
Recent events (2)
  • — I (S) $1817
  • — Z (S) $3634

1910.305 G01 IV D

Serious Gravity 1 1 instance 22 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(1)(iv)(D): Flexible cords and cables were used where attached to building surfaces.  Machine shop, interior wall; on or about 29 November 2016 and times prior thereto; an energized 25-foot extension cord, was used as permanent wiring and fastened to the wall with zip ties. This condition exposed employees to electrical shock and electrical burn hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G02 III

Serious Gravity 1 3 instances 22 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided that would prevent pull from being directly transmitted to joints or terminal screws.  Throughout the shop bay areas; on or about 29 November 2016 and times prior thereto; the employer did not ensure that strain relief was provided. Three instances were noted:       a. South bay; an energized electrical motor for the water cooler on a Miller Syncrowave 351 welding power source was not provided with strain relief. The power cord terminal fitting for the Emerson, model SA55NXSBT-2759, AC motor was separated from the switch box.       b. South bay, an energized electrical outlet box providing power for a Miller Welder unit was not provided with strain relief. The outlet box was missing the terminal fitting.        c. West bay, welding table; an energized four-place electrical outlet box was not provided with strain relief. The outlet box was missing the terminal fitting.  This condition exposed employees to an electrical shock and electrical burn hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.334 A02 I

Serious Gravity 1 6 instances 22 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.334(a)(2)(i): Portable cord and plug connected equipment and flexible cord sets (extension cords) were not visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket).  Throughout the shop bay areas; on or about 29 November 2016 and times prior thereto; the employer did not ensure that portable cord and plug connected equipment and flexible cord sets (extension cords) were visually inspected before use. Six instances were noted:       a. South bay, cutting area; an energized Miller XMT 304 CC/CU DC Inverter Arc Welder, serial number M8250511A, had a damaged power cord. Outer protective jacket was separated from the plug.        b. South bay, cutting area; an energized Miller XMT 304 CC/CU DC Inverter Arc Welder, serial number unknown, had a damaged power cord. Outer protective jacket was separated from the plug.        c. South bay, cutting area, ceiling mounted; an energized Reelcraft 40-foot, three place retractable reel cord had damaged to the outer protective jacket at the receptacle plug.        d. West bay, adjacent to shelving; a 25-foot heavy duty black extension cord had damaged to the outer protective jacket on multiple locations along the length of the cord.        e. South shop, work bench; an energized Hitachi G12SE2, Serial number MN20112, 4 1/2 inch,  Disc Grinder had damage to the power cord outer protective jacket.        f. West bay; an energized Jet 18-inch Woodworking Bandsaw, Model JWBS-18QT-3, Serial number 1001564, had damage to the power cord outer protective jacket adjacent to the plug.   This condition exposed employees to an electrical shock and electrical burn hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1915.134 B

Serious Gravity 1 2 instances 22 exposed
Issued
Abate by
Penalty
Initial $1817.00 · Current $909.00 Reduced
29 CFR 1915.134(b): Work rests were not kept a distance not to exceed 1/8 inch from the surface of the wheel.  West bay, welding bench area; on or about 29 November 2016 and times prior thereto; two instances were noted where the work rest on bench grinders were not properly adjusted not to exceed 1/8 inch from the abrasive wheel:       a. A Delta 8-inch Bench Grinder, Model 23-725, serial number 00052, the gap between the abrasive wheel and the work rest measured approximately 1/2 inch from the abrasive wheel on the right hand and 1/4 inch on the left hand side.        b. A Milwaukee 8-inch Bench Grinder, Model K56Y, serial number 604477SM815, the gap between the abrasive wheel and the work rest measured approximately 1/4 inch on the left and right hand sides.  This condition exposed employees to a caught in hazard.
Recent events (2)
  • — I (S) $908.5
  • — Z (S) $1817

1904.32 A01

Other-than-serious 3 instances 24 exposed
Issued
Abate by
Penalty
Initial $340.00 · Current $170.00 Reduced
29 CFR 1904.32(a)(1): The employer did not review the OSHA 300 log to verify that entries were complete and accurate, and correct any deficiencies identified.  Administrative office; on or about 29 November 2016 and times prior thereto; the company executive did not ensure that the OSHA 300A Summary of Work-related Injuries and Illness Log was accurate and complete, and/or deficiencies were identified and corrected at the end of the calendar year. Three instances were noted:       a. 2013 - OSHA Form 300A, number of cases in blocks (G), (H), (I), and (J); number of days away or restricted duty (K), and (L) not recorded; Injury and illness types partially entered, blocks (2-6) not entered.  Form not certified by company executive.         b. 2014 - OSHA Form 300A, number of cases in blocks (G), (H), (I), and (J); number of days away or restricted duty (K), and (L) not recorded; Injury and illness types partially entered, blocks (2-6) not entered. Form was certified on 19 February 2014.         c. 2015 - OSHA Form 300A, annual average number of employees block does not show the annual average number of employees or the total hours worked by all employees. Number of cases in blocks (G), (H), (I), and (J); number of days away or restricted duty (K), and (L) were not recorded; Injury and illness types partially entered, blocks (2-6) not entered. NAICS code not entered. Form not certified by company executive.    This condition leads to inaccurate reporting of injuries and illnesses.
Recent events (2)
  • — I (O) $170
  • — Z (O) $340

1904.32 A03

Other-than-serious 3 instances 24 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1904.32(a)(3): The employer did not certify an OSHA 300A Form or equivalent.  Administrative office; on or about 29 November 2016 and times prior thereto; the company executive did not certify the OSHA Form 300A or equivalent at the end of the calendar year. Three instances were noted:       a. 2013 - OSHA Form 300A; was not certified and signed by the company executive.       b. 2014 - OSHA Form 300A; was certified on 19 February 2014.            c. 2015  OSHA Form 300A; was not certified and signed by the company executive.  This condition leads to inaccurate reporting of injuries and illnesses.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.22 D01

Other-than-serious 1 instance 22 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.22(d)(1): On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate.  West bay; on or about 29 November 2016 and times prior thereto; the storage area on the mezzanine did not have the maximum safe load limit conspicuously posted. This condition exposed employees to a struck by hazard.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View BAY WELDING SERVICES, INC.'s full OSHA safety record →