Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DARREY MACHINE INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DARREY MACHINE INC. in 12001 W. CR 125, ODESSA, TX 79765 (NAICS 332710). OSHA activity number 341953511.

Watch Darrey Machine INC. — free Get an email when a new federal OSHA severe-injury report for Darrey Machine INC. is published. One employer, no account, unsubscribe in one click.
Establishment
DARREY MACHINE INC.
Site address
12001 W. CR 125
City
ODESSA
State
TX
ZIP
79765
Mailing
P O BOX 60541, MIDLAND, TX 79711
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
6
Ownership type
A

5 citations on file for this inspection.

1910.179 J02 IV

Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $2173.00 · Current $1304.00 Reduced
29 CFR 1910.179(j)(2)(iv): Monthly inspections of hoist chains, with a certification record which includes the date of inspection, the signature of the person who performed the inspection and an identifier of the chain which was inspected, were not performed:  Employees operating electric overhead hoists that had not been inspected monthly were exposed to struck-by hazards in the following instances:  1) Harrington 1 ton hoist.  2) Coffing 2 ton hoist.
Recent events (2)
  • — I (S) $1303.8
  • — Z (S) $2173

1910.303 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $3259.00 · Current $1955.00 Reduced
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees:  Employees operating a lighting fixture on a lathe having a deteriorated flexible cable to supply power were exposed to electrical shock hazards.
Recent events (2)
  • — I (S) $1955.4
  • — Z (S) $3259

1910.303 B02

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(b)(2): Installation and use. Listed or labeled equipment was not installed and used in accordance with any instructions included in the listing or labeling.  Employees were exposed to electrical shock hazards while welding when an electrical receptacle box was affixed to a flexible cable.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 B07 I

Serious Gravity 5 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxillary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substanially equivalent to the wall of the equipment:  Employees were exposed to electrical shock hazards when accessing the circuit breaker panels on the west wall which had openings that were not closed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 G01 IV A

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(1)(iv)(A): As a substitute for the fixed wiring of a structure;  Employees were exposed to electrical shock hazards while welding when flexible cable was used as a substitute for non metallic sheathed wiring.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341953511.