Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: ENGINEERED TRUSS SYSTEMS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ENGINEERED TRUSS SYSTEMS, INC. in 1400 E. BENSON ROAD, SIOUX FALLS, SD 57104 (NAICS 321214). OSHA activity number 341972438.

Watch Engineered Truss Systems, INC. — free Get an email when a new federal OSHA severe-injury report for Engineered Truss Systems, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1400 E. BENSON ROAD
City
SIOUX FALLS
State
SD
ZIP
57104
Mailing
1400 E. BENSON ROAD, SIOUX FALLS, SD 57104
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321214
Employees
15
Ownership type
A

3 citations on file for this inspection.

1910.147 C04 I

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $5070.00 · Current $3000.00 Reduced
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    (a) Engineered Truss Systems, Inc. at 1400 East Benson Road in Sioux Falls, SD 57104: On and before December 14, 2016 the employer did not ensure procedures were developed and utilized for energy control of the truss splicer prior to repair work being performed that exposed employees to caught-in hazards.     Abatement Note: Abatement certification and documentation is required for this item (see enclosed "Certification of Corrective Action Worksheet")
Recent events (2)
  • — I (S) $3000
  • — Z (S) $5070

1910.147 D

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):    (a)  Engineered Truss Systems, Inc. at 1400 East Benson Road in Sioux Falls, SD 57104: On and before December 14, 2016 the employer did not ensure the application of energy control was performed prior to repair work on the truss splicer. This condition exposed employees to caught-in hazards.     Abatement Note: Abatement certification and documentation is required for this item (see enclosed "Certification of Corrective Action Worksheet")
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C06

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2173.00 · Current $1000.00 Reduced
29 CFR 1910.147(c)(6): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.      (a)  Engineered Truss Systems, Inc. at 1400 East Benson Road in Sioux Falls, SD 57104: On and prior to December 14, 2016 the employer did not conduct periodic, at least annually, inspection of the energy control procedure to ensure compliance.      Abatement Note: Abatement certification  is required for this item (see enclosed "Certification of Corrective Action Worksheet")
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2173

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341972438.