HUMBLE, TX —
OSHA Inspection: JUAN FRANCISCO RODRIGUEZ
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of JUAN FRANCISCO RODRIGUEZ in 19304 HWY 59 N, HUMBLE, TX 77338 (NAICS 238170). OSHA activity number 341982437.
Where did this inspection happen?
- Establishment
- JUAN FRANCISCO RODRIGUEZ
- Site address
- 19304 HWY 59 N
- City
- HUMBLE
- State
- TX
- ZIP
- 77338
- Mailing
- 8903 C E KING PKWY #29, HOUSTON, TX 77044
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 1
- Ownership type
- A
Citations
3 citations on file for this inspection.
1926.451 C01
- Issued
- Abate by
- Penalty
- Initial $3741.00 · Current $3741.00
General-duty citation text
29 CFR 1926.451(c)(1): Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) were not restrained from tipping by guying, tying, bracing, or equivalent means, as set forth in subparagraphs (i) - (iii) of this paragraph. On or about December 19, 2016, on the north side of a Goodwill Store where employees were exposed to a fall hazard exceeding ten feet when performing siding work from fabricated frame scaffolding that was not restrained from tipping by guying, tying, bracing.
Recent events (1)
- — Z (S) $3741
1926.451 F03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: On or about December 19, 2016, on the north side of a Goodwill Store where employees were exposed to a fall hazard exceeding ten feet when performing siding work from fabricated frame scaffolding that was not inspected for visible defects by a competent person.
Recent events (1)
- — Z (S) $0
1926.452 C02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally: On or about December 19, 2016, on the north side of a Goodwill Store where employees were exposed to a fall hazard exceeding ten feet when performing siding work from fabricated frame scaffolding that was not braced by cross, horizontal, or diagonal braces to secure the members laterally.
Recent events (1)
- — Z (S) $0
More inspections in this industry (NAICS 238170)
CLINTON, MO—2026-07-14
TORCHYLO BUILDERS, LLC.
HIGH POINT, NC—2026-07-14
161545 - RHP SIDING LLC
HIGH POINT, NC—2026-07-14
161544 - TRIAD SIDING OF THOMASVILLE INCORPORATED
OXFORD, OH—2026-07-13
R&R SIDING LLC
WINSTON SALEM, NC—2026-07-10
161522 - MS SIDING LLC
More inspections in TX
WICHITA FALLS, TX—2026-07-16
UNITED RENTALS, INC.
SAN MARCOS, TX—2026-07-16
CASA MECHANICAL SERVICES, LTD.
CLARKSVILLE, TX—2026-07-15
SEQUOIAS TREE EXPERT LLC
EL PASO, TX—2026-07-15
SURE STEEL
CORPUS CHRISTI, TX—2026-07-15
NORTH STAR ENERGY SOLUTIONS LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341982437.