Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: TK POTABLE DIVING

Federal Agency inspection · Health discipline

On , OSHA opened a federal Agency health inspection of TK POTABLE DIVING in LINCOLN STREET- WATER TOWER, BRAINTREE, MA 02184 (NAICS 561990). OSHA activity number 341987220.

Watch TK Potable Diving — free Get an email when a new federal OSHA severe-injury report for TK Potable Diving is published. One employer, no account, unsubscribe in one click.
Establishment
TK POTABLE DIVING
Site address
LINCOLN STREET- WATER TOWER
City
BRAINTREE
State
MA
ZIP
02184
Mailing
PO. BOX 753, CROWLEY, TX 76036
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561990
Employees
3
Ownership type
A

8 citations on file for this inspection.

1910.420 A

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.420(a): The employer did not develop and maintain a safe practices manual:  Braintree Water Tank: A safe practices manual was not developed for employees performing a dive that involved cleaning and inspecting of a water tank with a water depth of approximately 57 feet.    The safe practice manual shall include required information as described in 1910.420( b)( 1) through (b)(2)(i-iv)
Recent events (1)
  • — Z (S) $0

1910.421 B

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.421(b): The employer did not maintain the following at the dive location: a list of the telephone or call numbers for an operational decompression chamber (if not at the dive location), accessible hospitals, available physicians, available means of transportation.   Braintree Water Tank: A list of the required phone numbers was not maintained for employees performing a dive that involved cleaning and inspecting of a water tank with a water level of approximately 57 feet.
Recent events (1)
  • — Z (S) $0

1910.421 D09

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.421(d)(9): Planning of a diving operation did not include an assessment of the safety and health aspects of the emergency procedures:  Braintree Water Tank: A dive plan, that assessed and provided for rescue during an underwater and/or above water emergency situation, was not developed for employees performing a dive that involved cleaning and inspecting of a water tank with a water depth of approximately 57 feet.
Recent events (1)
  • — Z (S) $0

1910.421 F01 II

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.421(f)(1)(ii): Dive team members were not briefed on the safety procedures for the diving mode:   Braintree Water Tank: The dive team members were not briefed on safety procedures including; 1) Methods to rescue an injured or incapacitated diver from the water tank, 2) Methods of communication during an emergency situation between the tender on top of the tank and team member on the ground, 3) Instructions to dive team to follow in event of restricted air flow through the main airline including use of the carried reserved breathing air supply (bailout tank) and pneumo line to provide air to the diver.
Recent events (1)
  • — Z (S) $0

1910.422 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.422(b)(1): The employer did not provide a means capable of supporting the diver for entering and exiting the water:  Braintree Water Tank: A portable ladder used for entering and exiting the water tank came loose, preventing a diver from being able to immediately exit the tank in an emergency situation.
Recent events (1)
  • — Z (S) $0

1910.422 B03

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.422(b)(3): The employer did not provide means to assist an injured diver from the water or into a bell:  Braintree Water Tower: There was no equipment available to assist an injured diver out of a water tank with a water depth of approximately 57 feet.
Recent events (1)
  • — Z (S) $0

1910.423 D01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.423(d)(1): The following information was not recorded and maintained for each diving operation:  Recorded information shall include(i) Names of dive team members (ii) Date, time, location(iii) diving modes used (iv) General nature of work performed (v) Appropriate underwater and surface conditions(vi) maximum depth and bottom time for each diver:  Braintree Water Tank: A dive log was not maintained for operations that occurred on 12-14-16 and 12-15-16 during a dive that involved cleaning and inspecting of a water tank with a water level of approximately 57 feet.
Recent events (1)
  • — Z (S) $0

1910.430 C03 II

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.430(c)(3)(ii): Umbilicals were not made of kink-resistant materials:  Braintree Water Tank: The main air hose to the diver helmet was not constructed of kink free material.
Recent events (1)
  • — Z (S) $0

USIC

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 341987220.