OSHA Inspection: JAVIER VENTO

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JAVIER VENTO in N. CONWAY AVE & W. GRIFFIN PKWY, MISSION, TX 78572 (NAICS 237110). OSHA activity number 342054053.

Watch Javier Vento — free Get an email when a new federal OSHA severe-injury report for Javier Vento is published. One employer, no account, unsubscribe in one click.
Establishment
JAVIER VENTO
Site address
N. CONWAY AVE & W. GRIFFIN PKWY
City
MISSION
State
TX
ZIP
78572
Mailing
3332 ISABELLA STREET, EDINBURG, TX 78541
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
3
Ownership type
A

3 citations on file for this inspection.

1926.651 C02

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $3803.00 · Current $3803.00
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees:  The employer did not ensure the use of an appropriate ladder or other safe means of access/egress for employees working, to install a valve, in a excavation at a depth greater than 5 (five) feet.
Recent events (1)
  • — Z (S) $3803

1926.651 K01

Serious Gravity 1 1 instance 2 exposed
Issued
Penalty
Initial $1630.00 · Current $1630.00
29 CFR 1926.651(k)(1): An inspection of the excavations, the adjacent areas, and protective systems was not conducted by the competent person prior to the start of work and as needed throughout the shift:  The employer did not ensure that a competent person conduct an inspection of the excavation site, prior to allowing employees to enter an excavation deeper than 5 (five) feet to conduct valve installation, exposing employees to engulfment hazards.
Recent events (1)
  • — Z (S) $1630

1926.652 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $3803.00 · Current $3803.00
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c). The employer had not complied with the provisions of 29 CFR 1926.652(b)(1)(i):  The employer did not ensure that employees, installing valves in an excavation greater than 5 feet in depth, were protected from engulfment hazards by the use of an approved protective system or shoring.
Recent events (1)
  • — Z (S) $3803