Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: KDK OF DAYTONA, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of KDK OF DAYTONA, INC. in JOHN ANDERSON DRIVE, ORMOND BEACH, FL 32176 (NAICS 238130). OSHA activity number 342058773.

Watch KDK OF Daytona, INC. — free Get an email when a new federal OSHA severe-injury report for KDK OF Daytona, INC. is published. One employer, no account, unsubscribe in one click.
Site address
JOHN ANDERSON DRIVE
City
ORMOND BEACH
State
FL
ZIP
32176
Mailing
555 W GRANADA BLVD. SUITE C4, ORMOND BEACH, FL 32174
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
7
Ownership type
A

3 citations on file for this inspection.

1926.102 A01

Serious Gravity 1 1 instance 2 exposed
Issued
Penalty
Initial $1630.00 · Current $604.00 Reduced
29 CFR 1926.102(a)(1): The employer shall ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation:    a. On or about January 25, 2017, employees using a Porter cable saw to cut wood were not wearing eye protection, exposing themselves to being struck by flying debris.
Recent events (2)
  • — I (S) $604
  • — Z (S) $1630

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $3803.00 · Current $1000.00 Reduced
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):    a. On or about January 25, 2017, roof area, two employees installing sheathing on a 5:12 pitch roof were not protected from up to a 30 feet fall hazard by the use of a fall protection system.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $3803

1926.1053 B04

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $3260.00 · Current $1000.00 Reduced
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed:    a. On or about January 25, 2017, employees used a Husky A-frame 12-foot step ladder in the closed position to access and exit from the roof area.  Employees were being exposed to a 12 feet fall hazard.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $3260

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342058773.