PERKINS, OK —
OSHA Inspection: HYDRO FOAM TECHONLOGY, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of HYDRO FOAM TECHONLOGY, INC. in 4321 E 122ND, PERKINS, OK 74059 (NAICS 325998). OSHA activity number 342083136.
Where did this inspection happen?
- Establishment
- HYDRO FOAM TECHONLOGY, INC.
- Site address
- 4321 E 122ND
- City
- PERKINS
- State
- OK
- ZIP
- 74059
- Mailing
- PO BOX 7, PERKINS, OK 74059
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325998
- Employees
- 7
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.132 F01
- Issued
- Abate by
- Penalty
- Initial $2173.00 · Current $1304.00 Reduced
General-duty citation text
29 CFR 1910.132(f)(1): The employer did not provide training to each employee who is required by this section to use personal protective equipment: On or about February 6, 2017 and times prior thereto, the employer did not train employees to know when personal protective equipment (PPE) is necessary and what PPE is necessary, including but not limited to hand protection. Employees are exposed to contact with chemicals and inhalation hazards.
Recent events (2)
- — I (S) $1303.8
- — Z (S) $2173
1910.1200 E01
- Issued
- Abate by
- Penalty
- Initial $3803.00 · Current $2282.00 Reduced
General-duty citation text
29 CFR 1910.1200(e)(1): Employer had not developed or implemented a written hazard communication program included the requirements outlined in 29 CFR 1910.1200(e)(1)(i) and (e)(1)(ii): On or about February 6, 2017, the employer did not develop and implement a written hazard communication program. Employees are exposed to contact with and inhalation hazards associated with chemical exposure.
Recent events (2)
- — I (S) $2281.8
- — Z (S) $3803
1910.1200 G08
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work shift to employees when they were in their work area(s): One or about June 16, 2017, and times prior thereto, the employer did not maintain copies of safety data sheets for each chemical in use in the facility and did not ensure copies of safety data sheets in the facility were accessible to employees during each work shift. Employees are exposed to contact with and inhalation hazards associated with chemical exposure.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.1200 H01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: On or about February 6, 2017 and times prior thereto, the employer did not provide effective information and training to employees who use chemicals such as, but not limited to, THPS-75, WITCONATE AOK, Ultranex NP 1000, OGI-4880, NS-9152, Alcoflow 920, CWF 610 and Nonoxynol 100. Employees are exposed to contact with and inhalation hazards associated with chemical exposure.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 C01
- Issued
- Abate by
- Penalty
- Initial $305.00 · Current $183.00 Reduced
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: On or about June 16, 2017, and times prior thereto, the employer did not establish and implement a written respiratory protection program prior to requiring employees to use respiratory protection. Employees are exposed to inhalation hazards.
Recent events (2)
- — I (O) $183
- — Z (O) $305
1910.134 E01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: On or about June 15, 2017, and times prior thereto, the employer did not provide each employee with a medical evaluation before requiring the employee to wear respiratory protection. Employees are exposed to inhalation and health hazards associated with respirator use.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 E04 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(e)(4)(i): The medical questionnaire was not administered confidentially during the employee's normal working hours or at a time and place convenient to the employee: On or about June 16, 2017, and times prior thereto, the employer did not administer the medical questionnaire confidentially to employees who are required to use respiratory protection.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 K03
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.134(k)(3): Training was not provided prior to requiring employees to use a respirator in the workplace: On or about June 16, 2017, and times prior thereto, the employer did not provide respiratory protection training to each employee prior to requiring that employee to wear respiratory protection. Employees are exposed to hazards associated with inhalation of hazardous chemicals.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 325998)
CHARLOTTE, TX—2026-07-07
CLEMENTS FLUIDS
KINDRED, ND—2026-06-29
ICE CRYSTAL ENGINEERING
WAYNESVILLE, NC—2026-06-23
161409 - PREMIER MAGNESIA, LLC
SOUTH PLAINFIELD, NJ—2026-06-17
AVINTHIA INC
WARMINSTER, PA—2026-06-12
CRC INDUSTRIES, INCORPORATED
More inspections in OK
MADILL, OK—2026-07-08
MID AMERICAN STEEL & WIRE CO., LLC
SEILING, OK—2026-06-26
GORE ENERGY
ADA, OK—2026-06-25
PAN AMERICA ELECTRIC , INC.
ADA, OK—2026-06-25
CITATION OIL & GAS CORPORATION
EDMOND, OK—2026-06-23
BRICK EXPERTS INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342083136.