SAN ANTONIO, TX —
OSHA Inspection: E.A.T. CONSTRUCTION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of E.A.T. CONSTRUCTION in 28411 VARIO LN., SAN ANTONIO, TX 78260 (NAICS 238140). OSHA activity number 342086899.
Where did this inspection happen?
- Establishment
- E.A.T. CONSTRUCTION
- Site address
- 28411 VARIO LN.
- City
- SAN ANTONIO
- State
- TX
- ZIP
- 78260
- Mailing
- 235 SERNA PARK, SAN ANTONIO, TX 78218
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 5
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.451 B01
- Issued
- Penalty
- Initial $2173.00 · Current $869.00 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of the scaffold was not fully planked or decked between the front uprights and the guardrail supports: a. South side residential home: On or about February 07, 2017, employees with no fall protection were exposed to falls, when working from a welded frame scaffold platform not fully planked, while installing the stone and brick veneer to the residential home. b. East side residential home: On or about February 07, 2017, employees with no fall protection were exposed to falls, when working from a welded frame scaffold platform not fully planked, while installing the stone and brick veneer to the residential home.
Recent events (2)
- — I (S) $869
- — Z (S) $2173
1926.451 B02
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(b)(2): Scaffold platforms and walkways were not at least 18 inches wide: a. South side residential home: On or about February 07, 2017, employees with no fall protection were exposed to falls, when working from a welded frame scaffold platform having only one 2X12 plank, while installing the stone and brick veneer to the residential home. b. East side residential home: On or about February 07, 2017, employees with no fall protection were exposed to falls, when working from a welded frame scaffold platform having only one 2X12 plank, while installing the stone and brick veneer to the residential home.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 C02
- Issued
- Penalty
- Initial $2173.00 · Current $869.00 Reduced
General-duty citation text
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation: a. South side residential home: On or about February 07, 2017, employees with no fall protection were exposed to falls, when working from a welded frame scaffold platform not having base plates, while installing the stone and brick veneer to the residential home. b. East side residential home: On or about February 07, 2017, employees with no fall protection were exposed to falls, when working from a welded frame scaffold platform not having base plates, while installing the stone and brick veneer to the residential home.
Recent events (2)
- — I (S) $869
- — Z (S) $2173
1926.451 C02 II
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(c)(2)(ii): Unstable objects were used to support scaffolds or platform units: a. South side residential home: On or about February 07, 2017, employees with no fall protection were exposed to falls, when working from a welded frame scaffold platform resting on a stack of bricks, while installing the stone and brick veneer to the residential home. b. East side residential home: On or about February 07, 2017, employees with no fall protection were exposed to falls, when working from a welded frame scaffold platform resting on unstable objects, while installing the stone and brick veneer to the residential home.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 E01
- Issued
- Penalty
- Initial $2173.00 · Current $869.00 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access: a. South side residential home: On or about February 07, 2017, employees with no fall protection were exposed to falls, when working from a welded frame scaffold platform not provided with a ladder, while installing the stone and brick veneer to the residential home. b. East side residential home: On or about February 07, 2017, employees with no fall protection were exposed to falls, when working from a welded frame scaffold platform not provided with a ladder, while installing the stone and brick veneer to the residential home.
Recent events (2)
- — I (S) $869
- — Z (S) $2173
1926.451 F07
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration: a. South side residential home: On or about February 07, 2017, employees with no fall protection were exposed to falls, when working from a welded frame scaffold platform not erected by competent persons, while installing the stone and brick veneer to the residential home. b. East side residential home: On or about February 07, 2017, employees with no fall protection were exposed to falls, when working from a welded frame scaffold platform not erected by competent persons, while installing the stone and brick veneer to the residential home.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 G04 I
- Issued
- Penalty
- Initial $2173.00 · Current $869.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms: a. South side residential home: On or about February 07, 2017, employees with no fall protection were exposed to falls, when working from a welded frame scaffold platform with no guard railing, while installing the stone and brick veneer to the residential home. b. East side residential home: On or about February 07, 2017, employees with no fall protection were exposed to falls, when working from a welded frame scaffold platform with no guard railing, while installing the stone and brick veneer to the residential home.
Recent events (2)
- — I (S) $869
- — Z (S) $2173
More inspections in this industry (NAICS 238140)
RENO, NV—2026-07-16
DC MASONRY
WINNETKA, IL—2026-07-15
CHICAGO STUCCO CO.
LODI, NJ—2026-07-15
J & O MASONRY CONTRACTORS
DORAVILLE, GA—2026-07-14
SUDLOW CONCRETE, INC.
FLAGLER BEACH, FL—2026-07-14
PLANET DESIGN SERVICES, INC.
More inspections in TX
WICHITA FALLS, TX—2026-07-16
UNITED RENTALS, INC.
SAN MARCOS, TX—2026-07-16
CASA MECHANICAL SERVICES, LTD.
CLARKSVILLE, TX—2026-07-15
SEQUOIAS TREE EXPERT LLC
EL PASO, TX—2026-07-15
SURE STEEL
CORPUS CHRISTI, TX—2026-07-15
NORTH STAR ENERGY SOLUTIONS LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342086899.