Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DOANE, LTD.

Unprogrammed Other inspection · Safety discipline

On , OSHA opened an unprogrammed Other safety inspection of DOANE, LTD. in N2960 730TH STREET, MENOMONIE, WI 54751 (NAICS 424510). OSHA activity number 342094240.

Watch Doane, LTD. — free Get an email when a new federal OSHA severe-injury report for Doane, LTD. is published. One employer, no account, unsubscribe in one click.
Establishment
DOANE, LTD.
Site address
N2960 730TH STREET
City
MENOMONIE
State
WI
ZIP
54751
Mailing
N2960 730TH STREET, MENOMONIE, WI 54751
Inspection type
Unprogrammed Other (I)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424510
Employees
10
Ownership type
A

8 citations on file for this inspection.

1910.132 D01

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $5070.00 · Current $2535.00 Reduced
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE):    (a) Throughout the establishment; A hazard assessment was not completed to determine what personal protective equipment would be required for protection against hazards present, while employees perform work inside electrical disconnect boxes.
Recent events (2)
  • — I (S) $2535
  • — Z (S) $5070

1910.335 A01 I

Serious Gravity 10 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not using electrical protective equipment that was appropriate for the specific parts of the body to be protected and for the work to be performed:  (a) Throughout the facility; Electrically rated personal protective equipment was not worn while troubleshooting and fuse replacement operations were performed in disconnect boxes.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.335 A01 II

Serious Gravity 10 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.335(a)(1)(ii): Protective equipment was not maintained in a safe, reliable condition and/or was not periodically inspected or tested:  (a) Throughout the establishment; Insulating electrical gloves were not air tested during pre-use inspection.  (b) Throughout the establishment; Insulating electrical gloves were not subjected to electrical testing every six months.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.272 G01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3622.00 · Current $1811.00 Reduced
29 CFR 1910.272(g)(1)(ii): Prior to bin entry, all mechanical, electrical, hydraulic, and pneumatic equipment which presented a danger to employees inside grain storage structures in the grain handling facility were not disconnected, locked out and tagged, blocked-off, or otherwise prevented from operating by other equally effective means or methods:    (a) Throughout the establishment; Electrical disconnect switches for drag chains were not isolated and locked out prior to employees entering corn and bean bins.
Recent events (2)
  • — I (S) $1811
  • — Z (S) $3622

1910.333 B02 I

Serious Gravity 10 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $5070.00 · Current $2535.00 Reduced
29 CFR 1910.333(b)(2)(i): The employer did not maintain a written copy of the procedures outlined in paragraph (b)(2) of 29 CFR 1910.333 and did not make it available for inspection by the Assistant Secretary of Labor and his or her authorized representatives:      (a) Throughout the establishment; Written electrical safe work procedures were not developed or maintained.
Recent events (2)
  • — I (S) $2535
  • — Z (S) $5070

1910.333 C02

Serious Gravity 10 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.333(c)(2): The employer did not ensure that only qualified persons were working on energized circuits and that qualified persons were familiar with the proper use of special precautionary techniques, personal protective equipment, insulating and shielding materials, and insulated tools:      (a) Throughout the establishment; Unqualified employees performed electrical work in disconnect boxes where energized components were present.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1904.32 A04

Other-than-serious 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $724.00 · Current $362.00 Reduced
29 CFR 1904.32(a)(4): The employer did not post an OSHA 300A Form or equivalent by February 1 thru April 30.    (a) Throughout the establishment; On or about February 9, 2017, the employer failed to complete and post the annual summary of injuries and illnesses for calendar year 2016.
Recent events (2)
  • — I (O) $362
  • — Z (O) $724

1904.40 A

Other-than-serious 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $724.00 · Current $362.00 Reduced
29 CFR 1904.40(a): The employer did not provide OSHA 300 Log information within 4 business hours.    (a) Throughout the establishment; On or about February 9, 2017, the employer did not provide a copy of their calendar year 2016 injury and illness logs.
Recent events (2)
  • — I (O) $362
  • — Z (O) $724

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342094240.