BILLINGS, MT —
OSHA Inspection: WOOD WISE CUSTOM CABINETS
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of WOOD WISE CUSTOM CABINETS in 10 N 19TH ST, BILLINGS, MT 59101 (NAICS 337110). OSHA activity number 342105707.
Where did this inspection happen?
- Establishment
- WOOD WISE CUSTOM CABINETS
- Site address
- 10 N 19TH ST
- City
- BILLINGS
- State
- MT
- ZIP
- 59101
- Mailing
- 10 N 19TH ST, BILLINGS, MT 59101
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 337110
- Employees
- 6
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.22 A01
- Issued
- Abate by
- Penalty
- Initial $1630.00 · Current $815.00 Reduced
General-duty citation text
29 CFR 1910.22(a)(1): (1) All places of employment, passageways, storerooms, service rooms, and walking-working surfaces are kept in a clean, orderly, and sanitary condition. a) Area behind Rover CNC Router: On or about February 15, 2017, employees are exposed to fire hazards from a build up of Class II combustible wood dust with an explosion severity of .61.
Recent events (2)
- — I (S) $815
- — Z (S) $1630
1910.28 B11 II
- Issued
- Abate by
- Penalty
- Initial $1630.00 · Current $815.00 Reduced
General-duty citation text
29 CFR 1910.28(b)(11)(ii): Each flight of stairs having at least 3 treads and at least 4 risers was not equipped with stair rail systems and handrails in accordance with Table D-2, Stairway Handrail Requirements: a) Stairway to Elevated Platform: On or about February 15, 2017and times prior, employees were exposed to fall hazards due to an incomplete stair rail system.
Recent events (2)
- — I (S) $815
- — Z (S) $1630
1910.147 C01
- Issued
- Abate by
- Penalty
- Initial $2716.00 · Current $1358.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) Holzma Optimat HPP 350 Beam Saw: On or about February 15, 2017 and at times prior,employees were exposed to amputation hazards while performing maintenance on machinery without following lockout procedures or having a lockout/tagout program in place. b) Brandt Ambition 1220 CNC Machine: On or about February 15, 2017 and at times prior, employees were exposed to amputation hazards while performing maintenance on machinery without following lockout procedures or having a lockout/tagout program in place. c) Rover B 4.40 FTK Router: On or about February 15, 2017 and at times prior, employees were exposed to amputation hazards while performing maintenance on machinery without following lockout procedures or having a lockout/tagout program in place.
Recent events (2)
- — I (S) $1358
- — Z (S) $2716
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $2173.00 · Current $1087.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Main Shop Area: On or about February 15, 2017 and at times prior, employees were exposed to caught in hazards from the rotating chuck on the Powermatic Drill Press model number PM2800B, serial number 13050557.
Recent events (2)
- — I (S) $1087
- — Z (S) $2173
1910.305 G01 IV B
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and cables may not be used where run through holes in walls, ceilings or floors: (a) Main Shop area: On or about February 15, 2017, and at time prior, a yellow flexible extension cord used to energize a Dayton electric fan was routed through a hole in a wall.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 337110)
OAKLAND PARK, FL—2026-07-16
PKB CABINETRY
ORLANDO, FL—2026-07-15
ROSTOV, LLC
RICHMOND HILL, GA—2026-07-14
WILSON CABINETRY, LLC
VESTAL, NY—2026-07-08
BARNWOOD KITCHEN CABINETS
DEERWOOD, MN—2026-07-02
111522 - DUFFNEY CUSTOM CABINETS LLC
More inspections in MT
HELENA, MT—2026-06-17
VANILLA BEAN BAKERY, LLC
HELENA, MT—2026-06-15
SKYWEST AIRLINES, INC.
MISSOULA, MT—2026-06-02
HD ROOFING, LLC
MISSOULA, MT—2026-06-02
RHINO ROOFING LLC
MANHATTAN, MT—2026-06-02
MONTANA ROOFING & SIDING PROS, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342105707.