Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CHAMPION MAINTENANCE CONTRACTORS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of CHAMPION MAINTENANCE CONTRACTORS, INC. in 656 NEW HAVEN AVENUE, DERBY, CT 06418 (NAICS 237110). OSHA activity number 342132149.

Watch Champion Maintenance Contractors, INC. — free Get an email when a new federal OSHA severe-injury report for Champion Maintenance Contractors, INC. is published. One employer, no account, unsubscribe in one click.
Site address
656 NEW HAVEN AVENUE
City
DERBY
State
CT
ZIP
06418
Mailing
211 SOUTH RIDGE STREET SUITE L, RYE BROOK, NY 10573
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
3
Ownership type
A

7 citations on file for this inspection.

1926.404 B01 II

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2716.00 · Current $1750.00 Reduced
29 CFR 1926.404(b)(1)(ii): Where an assured equipment grounding program was not utilized, receptacles were not protected with ground-fault circuit-interrupters when on a two-wire, single-phase portable or vehicle-mounted generator rated more than 5kW:    JOBSITE:   A ground fault circuit interrupter (GFCI) or an assured equipment grounding program was not used with the Generac GP 6500 Generator that powered a Red Lion Semi-Trash Pump.
Recent events (2)
  • — I (S) $1750
  • — Z (S) $2716

1926.652 A01

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $3803.00 · Current $2500.00 Reduced
29 CFR 1926.652(a)(1):  Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c):     JOBSITE:  The employees working in the 6 feet 8 inches to 7 feet 1 inch deep trench were not protected from cave-ins by utilizing appropriated cave-in protection systems/devices.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $3803

1926.651 J02

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary.  JOBSITE: The employer did not ensure that excavated material from the trench in which employees were working was placed at least 2 feet from the edge of the trench.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.651 H01

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $3803.00 · Current $2500.00 Reduced
29 CFR 1926.651(h)(1):  Employees shall not work in excavations in which there is accumulated water, or in excavations in which water is accumulating, unless adequate precautions have been taken to protect employees against the hazards posed by water accumulation. The precautions necessary to protect employees adequately vary with each situation, but could include special support or shield systems to protect from cave-ins, water removal to control the level of accumulating water, or use of a safety harness and lifeline.    JOBSITE:  Employees were working in a trench in which there was accumulated water, and/or water was accumulating without adequate precautions had been taken to protect employees against the hazards posed by water accumulation.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $3803

1926.651 I03

Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $3803.00 · Current $2500.00 Reduced
29 CFR 1926.651(i)(3): Sidewalks, pavements, or appurtenant structures had been undermined and a support system or another method was not provided to protect employees from the possible collapse of such structures:    JOBSITE:  Employees were working in a trench underneath a pavement which was undermined.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $3803

1926.1053 B01

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2716.00 · Current $1750.00 Reduced
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:    JOBSITE:  The side rails of the Werner 6-foot stepladder used by employees to get in and out of a trench, did not extend at least 3 feet above the upper landing surface.
Recent events (2)
  • — I (S) $1750
  • — Z (S) $2716

1926.1053 B04

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(b)(4): Ladders were used for purposes other than the purposes for which they were designed:  JOBSITE:  The Werner 6-foot stepladder was not used for the purpose for which it was designed; used in closed position.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342132149.