DERBY, CT —
OSHA Inspection: CHAMPION MAINTENANCE CONTRACTORS, INC.
Referral inspection · Safety discipline
At a glance
On , OSHA opened a referral safety inspection of CHAMPION MAINTENANCE CONTRACTORS, INC. in 656 NEW HAVEN AVENUE, DERBY, CT 06418 (NAICS 237110). OSHA activity number 342132149.
Where did this inspection happen?
- Establishment
- CHAMPION MAINTENANCE CONTRACTORS, INC.
- Site address
- 656 NEW HAVEN AVENUE
- City
- DERBY
- State
- CT
- ZIP
- 06418
- Mailing
- 211 SOUTH RIDGE STREET SUITE L, RYE BROOK, NY 10573
What kind of inspection was it?
- Inspection type
- Referral (C)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- Employees
- 3
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.404 B01 II
- Issued
- Abate by
- Penalty
- Initial $2716.00 · Current $1750.00 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(ii): Where an assured equipment grounding program was not utilized, receptacles were not protected with ground-fault circuit-interrupters when on a two-wire, single-phase portable or vehicle-mounted generator rated more than 5kW: JOBSITE: A ground fault circuit interrupter (GFCI) or an assured equipment grounding program was not used with the Generac GP 6500 Generator that powered a Red Lion Semi-Trash Pump.
Recent events (2)
- — I (S) $1750
- — Z (S) $2716
1926.652 A01
- Issued
- Penalty
- Initial $3803.00 · Current $2500.00 Reduced
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c): JOBSITE: The employees working in the 6 feet 8 inches to 7 feet 1 inch deep trench were not protected from cave-ins by utilizing appropriated cave-in protection systems/devices.
Recent events (2)
- — I (S) $2500
- — Z (S) $3803
1926.651 J02
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary. JOBSITE: The employer did not ensure that excavated material from the trench in which employees were working was placed at least 2 feet from the edge of the trench.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.651 H01
- Issued
- Penalty
- Initial $3803.00 · Current $2500.00 Reduced
General-duty citation text
29 CFR 1926.651(h)(1): Employees shall not work in excavations in which there is accumulated water, or in excavations in which water is accumulating, unless adequate precautions have been taken to protect employees against the hazards posed by water accumulation. The precautions necessary to protect employees adequately vary with each situation, but could include special support or shield systems to protect from cave-ins, water removal to control the level of accumulating water, or use of a safety harness and lifeline. JOBSITE: Employees were working in a trench in which there was accumulated water, and/or water was accumulating without adequate precautions had been taken to protect employees against the hazards posed by water accumulation.
Recent events (2)
- — I (S) $2500
- — Z (S) $3803
1926.651 I03
- Issued
- Penalty
- Initial $3803.00 · Current $2500.00 Reduced
General-duty citation text
29 CFR 1926.651(i)(3): Sidewalks, pavements, or appurtenant structures had been undermined and a support system or another method was not provided to protect employees from the possible collapse of such structures: JOBSITE: Employees were working in a trench underneath a pavement which was undermined.
Recent events (2)
- — I (S) $2500
- — Z (S) $3803
1926.1053 B01
- Issued
- Penalty
- Initial $2716.00 · Current $1750.00 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: JOBSITE: The side rails of the Werner 6-foot stepladder used by employees to get in and out of a trench, did not extend at least 3 feet above the upper landing surface.
Recent events (2)
- — I (S) $1750
- — Z (S) $2716
1926.1053 B04
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.1053(b)(4): Ladders were used for purposes other than the purposes for which they were designed: JOBSITE: The Werner 6-foot stepladder was not used for the purpose for which it was designed; used in closed position.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 237110)
CHANDLER, AZ—2026-07-16
PREMIER UNDERGROUND CONSTRUCTION LLC
HIGHLAND PARK, IL—2026-07-16
UNITED PLUMBING AND DRAIN, INC.
CHICAGO, IL—2026-07-15
SUSTAINABLE SEWER & WATER INC.
LAKE FOREST, IL—2026-07-15
GREVERS CORPORATION DBA NORTH SHORE BORING
CHEYENNE, WY—2026-07-15
AZTEC CONSTRUCTION
More inspections in CT
ENFIELD, CT—2026-07-16
MOMS ENFIELD
DAYVILLE, CT—2026-07-16
HARBOR FREIGHT
NEW BRITAIN, CT—2026-07-14
JANANII, LLC
NEWINGTON, CT—2026-07-14
TRUSS MANUFACTURING INC
NORTH BRANFORD, CT—2026-07-14
NYK STATEWIDE MOLINA CONSTRUCTION LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342132149.