Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: E DIAMOND ELECTRIC INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of E DIAMOND ELECTRIC INC. in 5312 N. NAVARRO, VICTORIA, TX 77901 (NAICS 238210). OSHA activity number 342143377.

Watch E Diamond Electric INC. — free Get an email when a new federal OSHA severe-injury report for E Diamond Electric INC. is published. One employer, no account, unsubscribe in one click.
Site address
5312 N. NAVARRO
City
VICTORIA
State
TX
ZIP
77901
Mailing
11525 BAUMAN ROAD, HOUSTON, TX 77076
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
15
Ownership type
A

3 citations on file for this inspection.

1926.651 C02

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $3622.00 · Current $1900.00 Reduced
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees.     At this workplace, employees conducted electrical work in excavations greater than four feet in depth and did not have a safe means of egress.
Recent events (2)
  • — I (S) $1900
  • — Z (S) $3622

1926.652 B02

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $3622.00 · Current $1900.00 Reduced
29 CFR 1926.652(b)(2): Maximum allowable slopes, and allowable configurations for sloping and benching systems, was not determined in accordance with the conditions and requirements set forth in Appendices A and B to this subpart.    At this workplace, employees conducted electrical work in excavations greater than five feet in depth and was not sloped or benched adequately in accordance with Appendices A and B to this subpart.
Recent events (2)
  • — I (S) $1900
  • — Z (S) $3622

1926.1053 B04

Other-than-serious 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed.    At this workplace employees conducted electrical work in excavations greater than four feet in depth and used a step ladder in the closed position for a means of access.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342143377.