Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: EAGLE MACHINE AND WELDING

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of EAGLE MACHINE AND WELDING in 304 WEST RAILROAD, SILVER LAKE, KS 66539 (NAICS 332999). OSHA activity number 342146545.

Watch Eagle Machine AND Welding — free Get an email when a new federal OSHA severe-injury report for Eagle Machine AND Welding is published. One employer, no account, unsubscribe in one click.
Site address
304 WEST RAILROAD
City
SILVER LAKE
State
KS
ZIP
66539
Mailing
304 WEST RAILROAD PO BOX 326, SILVER LAKE, KS 66539
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
2
Ownership type
A

6 citations on file for this inspection.

1910.212 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2173.00 · Current $1087.00 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and  Employees engaged in metal fabrication activities within the shop were exposed to work place hazards in that guarding was not provided to protect the operator.      a.) Employees engaged in machining parts activities, located at the east wall of the shop were exposed to struck by hazards in that the Sharp lathe chuck was not guarded.  b.) Employees engaged in cutting metal activities, located at the north side of the shop were exposed to laceration and amputation hazards in that the Ridgid horizontal band saw was not guarded.   c.) Employees engaged in cutting metal activities, located at the south wall of the shop were exposed to laceration and amputation hazards in that the Brilliant chop saw did not have a lower guard.
Recent events (2)
  • — I (S) $1086.5
  • — Z (S) $2173

1910.215 A04

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2173.00 · Current $1087.00 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch.  Employees engaged in metal grinding activities located at north side of shop were exposed to amputation and laceration hazard in that the Baldor bench grinder 712RE Serial.# W584 tool rest was 13/16 inches away from the abrasive wheel.
Recent events (2)
  • — I (S) $1086.5
  • — Z (S) $2173

1910.243 C03

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.243(c)(3): Abrasive wheels used on vertical portable grinder(s) (right angle head grinders) were not provided with safety guard(s) having a maximum exposure angle of 180 degrees and located between the operator and wheel.  Employees engaged in grinding metal activity within the shop were exposed to struck by hazards in that the DeWalt angle grinder 4.5 inch, serial# 030116 was not equipped with a guard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.253 B02 II

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2716.00 · Current $1358.00 Reduced
29 CFR 1910.253(b)(2)(ii): Inside of buildings, cylinders were not stored in a well-protected, well-ventilated, dry location, at least 20 feet (6.1 m) from highly combustible materials such as oil or excelsior.  Employees engaged in general shop procedures were exposed to fire and explosion hazards in that compressed oxygen cylinders tanks stored in southeast corner of the shop were not kept at least 20 feet from flammable cylinder tanks.
Recent events (2)
  • — I (S) $1358
  • — Z (S) $2716

1910.303 B01 I

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1630.00 · Current $815.00 Reduced
29 CFR 1910.303(b)(1)(i): Electrical equipment was not free from recognized hazards likely to cause death or serious physical harm, in that the employer did not ensure that the electrical equipment had listing or labeling that identifying the purpose for which it was intended.  Employees engaged in welding activities located throughout the shop were exposed to electrical hazards in that damaged electrical cords for welders were repaired using tape and outlet boxes.  a. Hypertherm Power Max 900 Welder.  b. Airco CV 200II Welder.
Recent events (2)
  • — I (S) $815
  • — Z (S) $1630

1910.303 G01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1630.00 · Current $815.00 Reduced
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment.  Employees engaged in general shop procedures were exposed to electrical hazards in that access to the circuit breaker panel located on west wall was blocked by the metal compressed air line.
Recent events (2)
  • — I (S) $815
  • — Z (S) $1630

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342146545.