Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: ENERGY TRANSFER SOLUTIONS, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ENERGY TRANSFER SOLUTIONS, LLC in 1201 N. ORANGE STREET 9TH FLOOR, WILMINGTON, DE 19801 (NAICS 811310). OSHA activity number 342148699.

Watch Energy Transfer Solutions, LLC — free Get an email when a new federal OSHA severe-injury report for Energy Transfer Solutions, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1201 N. ORANGE STREET 9TH FLOOR
City
WILMINGTON
State
DE
ZIP
19801
Mailing
425 MCFARLAN ROAD SUITE 209, KENNETT SQUARE, PA 19348
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811310
Employees
1
Ownership type
A

2 citations on file for this inspection.

1904.39 A02

Other-than-serious 1 instance 1 exposed
Issued
Penalty
Initial $5387.00 · Current $3771.00 Reduced
29 CFR 1904.39(a)(2): The employer did not report an in-patient hospitalization, amputation, or loss of an eye as a result of a work-related incident to OSHA within twenty-four (24) hours.  a) 1201 N. Orange Street, 9th Floor, Wilmington, DE - On or about March 1, 2017, the employer failed to report an in-patient hospitalization as a result of a work-related incident within twenty-four (24) hours of February 27, 2017.
Recent events (2)
  • — I (O) $3770.9
  • — Z (O) $5387

1910.147 C04 II

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):     a) 1201 N. Orange Street, 9th Floor, Wilmington DE - On or about February 27, 2017, specific energy control procedures were not utilized by an employee servicing HVAC equipment, who sustained a minor electrical shock.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342148699.