Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JOSE LUIS NUNEZ ROOFING

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JOSE LUIS NUNEZ ROOFING in 909 COVE TRAIL, EULESS, TX 76039 (NAICS 238160). OSHA activity number 342170891.

Watch Jose Luis Nunez Roofing — free Get an email when a new federal OSHA severe-injury report for Jose Luis Nunez Roofing is published. One employer, no account, unsubscribe in one click.
Site address
909 COVE TRAIL
City
EULESS
State
TX
ZIP
76039
Mailing
1705 LAGONDA AVE, FORT WORTH, TX 76164
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
6
Ownership type
A

3 citations on file for this inspection.

1926.102 A01

Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $1630.00 · Current $1630.00
29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury:     At a new residential construction site, employees operating pneumatic nail guns were not protected from eye injuries by wearing protective eyewear.
Recent events (1)
  • — Z (S) $1630

1926.501 B13

Serious Gravity 10 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $3803.00 · Current $3803.00
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6-feet or more above lower levels was not protected by guardrail systems, safety net system, or personal fall arrest systems, nor was an alternative fall protection plan which meets the requirements of '1926.502(k) developed and implemented.    At a new residential construction site, employees installing shingles on the roof without fall protection were exposed to fall hazards of approximately 18 feet.
Recent events (1)
  • — Z (S) $3803

1926.1053 B01

Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $1630.00 · Current $1630.00
29 CFR 1926.1053(b)(1):  When portable ladders were used for access to an upper landing surface, the ladder side rails was not extended at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access:    At a new residential construction site, employees used ladders not extended at least 3 feet above the upper landing to access the roof were exposed to fall hazards.
Recent events (1)
  • — Z (S) $1630

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342170891.