TUSCALOOSA, AL —
OSHA Inspection: TIP TOP STUCCO CONSTRUCTION
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of TIP TOP STUCCO CONSTRUCTION in 936 22ND AVE E, TUSCALOOSA, AL 35404 (NAICS 238140). OSHA activity number 342182656.
Where did this inspection happen?
- Establishment
- TIP TOP STUCCO CONSTRUCTION
- Site address
- 936 22ND AVE E
- City
- TUSCALOOSA
- State
- AL
- ZIP
- 35404
- Mailing
- 165 DEERMANS CHAPEL RD, STEELE, AL 35987
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 6
- Ownership type
- A
Citations
7 citations on file for this inspection.
1926.100 A
- Issued
- Penalty
- Initial $3259.00 · Current $1955.00 Reduced
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: (a) On or about 3/15/2017 - at Section/Building 3, 936 22nd Ave E, Tuscaloosa, Al, an employee was exposed to overhead struck by hazards while working without head protection during the application of exterior insulation and finish system (Dryvit) from underneath a scaffold platform.
Recent events (2)
- — I (S) $1955.4
- — Z (S) $3259
1926.451 H01
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(h)(1): Each employee on a scaffold was not provided with additional protection from falling hand tools, debris, and other small objects through the installation of toeboards, screens, guardrail systems, or through the erection of debris nets, catch platforms, or canopy structures that contain or deflect the falling objects. For falling objects too large, heavy or massive to be contained or deflected, the employer did not place and secure such potential falling objects away from the edge of the surface from which they could fall: (a) On or about 3/15/2017 - at Section/Building 3, 936 22nd Ave E, Tuscaloosa, Al, additional protection from falling hand tools, debris, and other small objects was not provided for an employee who was applying exterior insulation and finish system (Dryvit) from a scaffold platform while another employee was also applying Dryvit from a scaffold platform above him.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 B01
- Issued
- Penalty
- Initial $3803.00 · Current $2282.00 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii): (a) On or about 3/15/2017 - at Section/Building 1, 936 22nd Ave E, Tuscaloosa, Al, an employee applying exterior insulation and finish system (Dryvit) on a column was working from a scaffold platform that was not fully planked. (b) On or about 3/15/2017 - at Section/Building 3, 936 22nd Ave E, Tuscaloosa, Al, employees applying exterior insulation and finish system (Dryvit) on a wall were working from scaffold platforms that were not fully planked.
Recent events (2)
- — I (S) $2281.8
- — Z (S) $3803
1926.451 E01
- Issued
- Penalty
- Initial $3803.00 · Current $2282.00 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access: (a) On or about 3/15/2017 - at Section/Building 1, 936 22nd Ave E, Tuscaloosa, Al, a ladder or other means of access was not provided for an employee that was applying exterior insulation and finish system (Dryvit) from a fabricated frame scaffold approximately 19 feet above the ground. (b) On or about 3/15/2017 - at Section/Building 3, 936 22nd Ave E, Tuscaloosa, Al, a ladder or other means of access was not provided for employees applying exterior insulation and finish system (Dryvit) from a fabricated frame scaffold approximately 11 feet and 4.5 feet from the ground.
Recent events (2)
- — I (S) $2281.8
- — Z (S) $3803
1926.451 G01
- Issued
- Penalty
- Initial $3803.00 · Current $2282.00 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: (a) On or about 3/15/2017 - at Section/Building 1, 936 22nd Ave E, Tuscaloosa, Al, an employee was not protected from falling approximately 19 feet while applying exterior insulation and finish system (Dryvit) from a fabricated frame scaffold. (b) On or about 3/15/2017 - at Section/Building 3, 936 22nd Ave E, Tuscaloosa, Al, an employee was not protected from falling approximately 11 feet while applying exterior insulation and finish system (Dryvit) from a fabricated frame scaffold.
Recent events (2)
- — I (S) $2281.8
- — Z (S) $3803
1926.452 C02
- Issued
- Penalty
- Initial $3803.00 · Current $2282.00 Reduced
General-duty citation text
29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally: (a) On or about 3/15/2017 - at Section/Building 1, 936 22nd Ave E, Tuscaloosa, Al, an employee was applying exterior insulation and finish system (Dryvit) from a fabricated frame scaffold that was not fully braced at the two top sections due to the diagonal braces missing on the side adjacent to the building. (b) On or about 3/15/2017 - at Section/Building 3, 936 22nd Ave E, Tuscaloosa, Al, employees were applying exterior insulation and finish system (Dryvit) from a fabricated frame scaffold that was not fully braced across all sections due to diagonal braces missing on the side adjacent to the wall and the scaffold sections were not secured together laterally.
Recent events (2)
- — I (S) $2281.8
- — Z (S) $3803
1926.501 B01
- Issued
- Penalty
- Initial $3803.00 · Current $2282.00 Reduced
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. (a) On or about 3/15/2017 - at Section/Building 1, 936 22nd Ave E, Tuscaloosa, Al, employees were not protected from falling approximately 13.6 feet while applying exterior insulation and finish system (Dryvit) from an unprotected balcony.
Recent events (2)
- — I (S) $2281.8
- — Z (S) $3803
More inspections in this industry (NAICS 238140)
MARIANNA, FL—2026-07-13
PRIMETIME MOBILE MASONRY LLC
LOMPOC, CA—2026-07-10
UNKNOWN EMPLOYER
FREEHOLD, NJ—2026-07-10
CRAIG'S MASONRY & HARDSCAPE LLC
CINCINNATI, OH—2026-07-09
ALL AMERICAN CONCRETE LLC
NEW YORK, NY—2026-07-08
JEY CONSTRUCTIONS WORKS CORP
More inspections in AL
CLANTON, AL—2026-07-13
UBIQUE TECHNOLOGIES, INC.
IRONDALE, AL—2026-07-13
FATHER NATURE LANDSCAPES OF BIRMINGHAM, INC.
GARDENDALE, AL—2026-07-09
ANDINO'S IRON WORKERS, LLC
CULLMAN, AL—2026-07-09
ALFREDO PICHARDO BLANCO
MOBILE, AL—2026-07-09
FLEXICREW TECHNICAL, LLC
Source