Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: BENNY'S ROOFING LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BENNY'S ROOFING LLC in 1299 BOURDEAXU WAY, SPRINGBORO, OH 45066 (NAICS 238160). OSHA activity number 342209863.

Watch Benny'S Roofing LLC — free Get an email when a new federal OSHA severe-injury report for Benny'S Roofing LLC is published. One employer, no account, unsubscribe in one click.
Establishment
BENNY'S ROOFING LLC
Site address
1299 BOURDEAXU WAY
City
SPRINGBORO
State
OH
ZIP
45066
Mailing
463 CAMBRIDGE DR., CINCINNATI, OH 45241
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
1
Ownership type
A

2 citations on file for this inspection.

1926.1053 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $2988.00 · Current $2988.00
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.  On March 30, 2017, at 1299 Bourdeaux Way, Clearcreek Township, a condominium under construction a roofer was exposed to a 10' fall hazard while using a metal extension ladder that only extended 30 inches above the eave of the roof.
Recent events (1)
  • — Z (S) $2988

1926.501 B13

Repeat Gravity 10 1 instance 1 exposed
Issued
Penalty
Initial $8366.00 · Current $8366.00
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems.  On March 30, 2017, at 1299 Bourdeaux Way, Clearcreek Township, a condominium under construction, a roofer was exposed to an 10' fall hazard while installing roof vents on an 8/12 pitch roof without utilizing any fall protection.   Benny's Roofing LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard, which was contained in OSHA inspection number 1205314, citation number 1, item number 1and was affirmed as a final order on March 7, 2017, with respect to a workplace located at 8082 Big Oak Circle, Mason, OH 45040.
Recent events (1)
  • — Z (R) $8366

View BENNY'S ROOFING LLC's full OSHA safety record →