Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: WISCONSIN CORRUGATED PALLETS, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of WISCONSIN CORRUGATED PALLETS, INC. in 1410 HEGGEN STREET, HUDSON, WI 54016 (NAICS 322211). OSHA activity number 342210416.

Watch Wisconsin Corrugated Pallets, INC. — free Get an email when a new federal OSHA severe-injury report for Wisconsin Corrugated Pallets, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1410 HEGGEN STREET
City
HUDSON
State
WI
ZIP
54016
Mailing
1410 HEGGEN STREET, HUDSON, WI 54016
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
322211
Employees
17
Ownership type
A

13 citations on file for this inspection.

1910.147 C04 II B

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $5071.00 · Current $2535.00 Reduced
29 CFR 1910.147(c)(4)(ii)(B): The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy:    (a) Production area; The general energy isolation procedure did not identify where or how to isolate electrical energy on the blue slitter, which did not have a readily identifiable isolation point near the machine.
Recent events (2)
  • — I (S) $2535
  • — Z (S) $5071

1910.147 C07 I B

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $5071.00 · Current $2536.00 Reduced
29 CFR 1910.147(c)(7)(i)(B): Each affected employee was not instructed in the purpose and use of the energy control procedure:    (a) Throughout the production area; Affected employees were not instructed in the purpose and use of energy control procedures.
Recent events (2)
  • — I (S) $2536
  • — Z (S) $5071

1910.147 C07 III B

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(7)(iii)(B): Additional retraining was not conducted whenever a periodic inspection under paragraph (c)(6) of 29 CFR 1910.147 reveals, or whenever the employer has reason to believe that there are deviations from or inadequacies in the employee's knowledge or use of the energy control procedures:  (a) Production area; Additional retraining for lockout was not conducted as required when it was identified that energy control procedures were not being used during all setup operations on a slitter.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C07 IV

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(7)(iv): The employer did not certify that employee training had been accomplished and kept up to date:  (a) Throughout the production area; Certification of lockout training was not maintained and/or available.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 D03

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $5071.00 · Current $2536.00 Reduced
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment was not physically located and operated in such a manner as to isolate the machine or equipment from the energy source:    (a) Production area; Energy isolation devices were not used to isolate energy sources during setup operations on equipment including, but not limited to; the blue slitter.
Recent events (2)
  • — I (S) $2536
  • — Z (S) $5071

1910.147 D04 I

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:    (a) Production area; Lockout devices were not affixed to energy isolation points during setup operations on equipment including, but not limited to; the blue slitter.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 2 instances 4 exposed
Issued
Abate by
Penalty
Initial $4345.00 · Current $2173.00 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    (a) Production area; Guarding was not provided for rotating parts on equipment including, but not limited to; a drill press and vertical milling machine.
Recent events (2)
  • — I (S) $2173
  • — Z (S) $4345

1910.212 A03 II

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $5071.00 · Current $2535.00 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation guards were not designed and constructed to prevent the operator from having any part of his/ her body in the danger zone during the operating cycle:    (a) Production area; On or about March 20, 2017, point of operation guarding on a beam saw was not designed and installed to prevent operators from being exposed to the saw blade.
Recent events (2)
  • — I (S) $2535
  • — Z (S) $5071

1910.305 B01 II

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $5071.00 · Current $2536.00 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:    (a) Production area; Energized parts of the bus bar inside service panel P4 were exposed through an unused circuit breaker opening.
Recent events (2)
  • — I (S) $2536
  • — Z (S) $5071

1910.305 B02 I

Serious Gravity 10 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(2)(i): All pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:  (a) Production area; A cover plate was not installed on a junction box that contained energized conductors.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1904.4 A

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $724.00 · Current $362.00 Reduced
29 CFR 1904.4(a): The employer did not keep records -OSHA 300 form, Log of Work Related Injuries and Illnesses; 300-A form, Summary or Work-Related Injuries and Illnesses; and 301 form, Injury and Illness Incident Report:    (a) Throughout the facility; On or about March 30, 2017, OSHA form 300 and form 300-A records of employee injuries and illnesses were not maintained.
Recent events (2)
  • — I (O) $362
  • — Z (O) $724

1910.147 C05 II B

Other-than-serious 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(5)(ii)(B): Lockout and tagout devices were not standardized within the facility in at least one of the following criteria; color, shape, or size:  (a) Production area; Lockout locks were not standardized.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 F02

Other-than-serious 2 instances 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  (a) Production area; Each circuit breaker in panel P4 was not labeled to identify its purpose.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342210416.