Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: CALDERON TREE SERVICES

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of CALDERON TREE SERVICES in 4000 DEEPWOOD RD., COLLEYVILLE, TX 76034 (NAICS 561730). OSHA activity number 342228913.

Watch Calderon Tree Services — free Get an email when a new federal OSHA severe-injury report for Calderon Tree Services is published. One employer, no account, unsubscribe in one click.
Site address
4000 DEEPWOOD RD.
City
COLLEYVILLE
State
TX
ZIP
76034
Mailing
1819 SCHOOL RD., CARROLLTON, TX 75006
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
561730
Employees
3
Ownership type
A

4 citations on file for this inspection.

1910.332 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2716.00 · Current $2716.00
29 CFR 1910.332(b)(1): Employees were not trained in and familiar with the safety-related work practices required by 1910.331 through 1910.335 that pertained to their respective job assignments.  At the jobsite, an employee trimming tree branches was not trained in safety-related work practices when working near or in the vicinity of energized overhead power lines, exposing the employee to the hazards of electric shock, severe burns and electrocution.
Recent events (1)
  • — Z (S) $2716

1910.333 C03 I A

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $12675.00 · Current $12675.00
29 CFR 1910.333(c)(3)(i)(A): When an unqualified person is working in an elevated position near overhead lines, the location shall be such that the person and the longest conductive object he or she may contact cannot come closer to any unguarded, energized overhead line than the following distances:  (1)  For voltages to ground 50kV or below - 10 feet (305 cm); (2)  For voltages to ground over 50kV - 10 feet (305 cm) plus 4 inches (10 cm) for every 10kV over 50kV.  At the jobsite, an employee performing tree trimming activities and the employer did not ensure that unqualified personnel working in an elevated position and the longest conductive objects maintained the required distances from any unguarded, energized overhead power line exposing the employee to electric shock, severe burns and electrocution.
Recent events (1)
  • — Z (S) $12675

1910.335 A02 I

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.335(a)(2)(i): Employees did not use insulated tools or handling equipment that might make contact with such conductors or parts when working near exposed energized conductors or circuit parts.   At the jobsite, an employee trimming tree branches with a non-insulated, 20 foot telescoping aluminum pole saw did not keep the required clearance distances from overhead energized power lines, exposing the employee to electric shock, severe burns and electrocution hazards.
Recent events (1)
  • — Z (S) $0

1904.39 A01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $5000.00 · Current $5000.00
29 CFR 1904.39(a)(1): The employer did not report within 8-hours the death of an employee resulting from a work-related incident.   The violation occurred on April 3, 2017, the employer failed to report to OSHA a work related fatality prior to the elapse of eight (8) hours reporting period of the incident.
Recent events (1)
  • — Z (O) $5000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342228913.