BUTTE, MT —
OSHA Inspection: PIONEER CONCRETE & FUEL, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PIONEER CONCRETE & FUEL, INC. in 825 MARYLAND AVENUE, BUTTE, MT 59702 (NAICS 327320). OSHA activity number 342229325.
Where did this inspection happen?
- Establishment
- PIONEER CONCRETE & FUEL, INC.
- Site address
- 825 MARYLAND AVENUE
- City
- BUTTE
- State
- MT
- ZIP
- 59702
- Mailing
- PO BOX 3207, BUTTE, MT 59702
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 327320
- Employees
- 16
- Ownership type
- A
Citations
2 citations on file for this inspection.
1910.253 B04 III
- Issued
- Abate by
- Penalty
- Initial $2897.00 · Current $1738.00 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour: a) East Wall Outside Batch Plant: On or about April 5, 2017 and at times prior, employees were exposed to fire, and explosion hazards. Oxygen and Acetylene Cylinders, were not separated at least 20 feet.
Recent events (2)
- — I (S) $1738.2
- — Z (S) $2897
1910.303 B02
- Issued
- Abate by
- Penalty
- Initial $2173.00 · Current $1304.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) Batch Plant Power Tap: On or about April 5, 2017 and at times prior, employees were exposed to electrical shock and fire hazards associated with a Relocatable Power Tap used to provide energy to multiple pieces of equipment.
Recent events (2)
- — I (S) $1303.8
- — Z (S) $2173
More inspections in this industry (NAICS 327320)
RENO, NV—2026-07-09
R&K READY MIXED CONCRETE, LLC
RENO, NV—2026-07-09
R&K READY MIXED CONCRETE, LLC
MOUNT VERNON, IL—2026-07-08
BEELMAN READY-MIX INC
STOCKTON, CA—2026-07-07
A & A CONCRETE SUPPLY, INC.
LA CROSSE, WI—2026-07-07
RIVER CITY READY MIX, INC.
More inspections in MT
HELENA, MT—2026-06-17
VANILLA BEAN BAKERY, LLC
HELENA, MT—2026-06-15
SKYWEST AIRLINES, INC.
MISSOULA, MT—2026-06-02
HD ROOFING, LLC
MISSOULA, MT—2026-06-02
RHINO ROOFING LLC
MANHATTAN, MT—2026-06-02
MONTANA ROOFING & SIDING PROS, LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342229325.