Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PIVOT POINT, INCORPORATED

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of PIVOT POINT, INCORPORATED in 761 INDUSTRIAL LANE, HUSTISFORD, WI 53034 (NAICS 332510). OSHA activity number 342242047.

Watch Pivot Point, Incorporated — free Get an email when a new federal OSHA severe-injury report for Pivot Point, Incorporated is published. One employer, no account, unsubscribe in one click.
Site address
761 INDUSTRIAL LANE
City
HUSTISFORD
State
WI
ZIP
53034
Mailing
P.O. BOX 488, HUSTISFORD, WI 53034
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332510
Employees
63
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 II C

Serious Gravity 5 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $5070.00 · Current $3549.00 Reduced
29 CFR 1910.147(c)(4)(ii)(C): Specific procedural steps for the placement, removal and transfer of lockout devices or tagout devices and the responsibility for them; and  On or about April 11, 2017 written energy control procedures were not developed for SLIC 2 and SLIC 3 machines.
Recent events (2)
  • — I (S) $3549
  • — Z (S) $5070

1910.147 C04 II D

Serious Gravity 5 2 instances 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(4)(ii)(D): The energy control procedures did not clearly and specifically outline the requirements for testing a machine or equipment to determine and verify the effectiveness of lockout devices, tagout devices, and other energy control  On or about April 11, 2017 written energy control procedures were not developed for SLIC 2 and SLIC 3 machines.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 D04 I

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $5070.00 · Current $3549.00 Reduced
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:  On or about April 11, 2017 employee operating the SLIC 3 machine did not isolate the energy during set-up adjustments in station 30.
Recent events (2)
  • — I (S) $3549
  • — Z (S) $5070

1910.147 D03

Serious Gravity 5 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment was not physically located and operated in such a manner as to isolate the machine or equipment from the energy source:  On or about April 11, 2017 employee operating the SLIC 3 machine did not isolate the energy during set-up adjustments in station 30.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342242047.