HOULTON, WI —
OSHA Inspection: ALPHA POWERSPORT INCORPORATED
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of ALPHA POWERSPORT INCORPORATED in 1412 COUNTY ROAD V, HOULTON, WI 54082 (NAICS 336991). OSHA activity number 342242526.
Where did this inspection happen?
- Establishment
- ALPHA POWERSPORT INCORPORATED
- Site address
- 1412 COUNTY ROAD V
- City
- HOULTON
- State
- WI
- ZIP
- 54082
- Mailing
- 1412 COUNTY ROAD V, HOULTON, WI 54082
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 336991
- Employees
- 6
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.28 B01 I
- Issued
- Abate by
- Penalty
- Initial $3803.00 · Current $3803.00
General-duty citation text
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that is 4 feet (1.2m) or more above a lower level was protected from falling by guardrail systems, safety net system, or personal fall arrest system: (a) Southeast mezzanine; A guardrail or other acceptable means of fall protection was not provided for an open side on the elevated mezzanine.
Recent events (3)
- — A (S) $3803
- — I (S) $2320
- — Z (S) $3803
1910.29 F01 I
- Issued
- Abate by
- Penalty
- Initial $1630.00 · Current $1630.00
General-duty citation text
29 CFR 1910.29(f)(1)(i): (i) Handrails are not less than 30 inches (76 cm) and not more than 38 inches (97 cm), as measured from the leading edge of the stair tread to the top surface of the handrail (see Figure D-12): (a) Southeast mezzanine stairway; The handrail was not installed between 30-38 inches above the stair treads.
Recent events (3)
- — A (S) $1630
- — I (S) $1000
- — Z (S) $1630
1910.29 F02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.29(f)(2): The employer did not ensure that a minimum finger clearance of 2.25 inches (5.7 cm) was maintained between handrails and any other object: (a) Southeast mezzanine stairway; There was less than 2.25 inches of finger clearance between the handrail and wall it was mounted to.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $2716.00 · Current $2716.00
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: (a) Frame building area; Guarding was not provided for rotating parts and flying chips on equipment, including but not limited to; a drill press and horizontal band saw.
Recent events (3)
- — A (S) $2716
- — I (S) $1850
- — Z (S) $2716
1910.242 B
- Issued
- Abate by
- Penalty
- Initial $2173.00 · Current $2173.00
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: (a) Shop area; Air guns used for cleaning activities were not equipped with devices to reduce air pressure to less than 30 p.s.i.
Recent events (3)
- — A (S) $2173
- — I (S) $1850
- — Z (S) $2173
1910.303 B07 I
- Issued
- Abate by
- Penalty
- Initial $1630.00 · Current $1630.00
General-duty citation text
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment: (a) Engineering office/photography area; Unused circuit breaker openings in a service panel were not covered with materials that were equal to the strength of the equipment wall.
Recent events (3)
- — A (S) $1630
- — I (S) $980
- — Z (S) $1630
1910.305 B01 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(b)(1)(i): Conductors entering cutout boxes, cabinets, or fittings shall be protected from abrasion, and openings through which conductors enter were not effectively closed: (a) Engineering office/photography area; Conductors were not protected from abrasions and openings through which conductors entered a junction box that was not effectively closed as required.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.305 B02 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(b)(2)(i): All pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose: (a) Engineering office/photography area; A faceplate was not installed on a junction box that contained energized conductors for a receptacle.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: (a) Engineering office/photography area; Relocatable power taps were installed in series (daisy-chained).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G01 IV A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: (a) Engineering office/photography area; An extension cord and relocatable power taps were used as a substitute for permanent wiring.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 336991)
VACAVILLE, CA—2026-04-30
PACIFIC CYCLE INC.
BEND, OR—2026-01-15
317742982 - ARGONAUT LLC
EUGENE, OR—2025-12-11
317742678 - RPA CYCLING INC
RICHARDSVILLE, KY—2025-11-07
68549 - RC COMPONENTS INC
PORTLAND, OR—2025-09-15
317741786 - KING CYCLE GROUP INC
More inspections in WI
MUSCODA, WI—2026-07-10
SCOT INDUSTRIES, INC
FRANKLIN, WI—2026-07-10
EDGE BROADBAND SOLUTIONS LLC
APPLETON, WI—2026-07-10
LAWRENCE UNIVERSITY OF WISCONSIN
KIMBERLY, WI—2026-07-10
ENRIQUE RESENDIC
SLINGER, WI—2026-07-10
DYLAN MATTHEW SHELLEY LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342242526.