OSHA Inspection: SETO VARGAS UTILITIES, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of SETO VARGAS UTILITIES, INC. in WEISS LANE / JESSE BOHLS DR., PFLUGERVILLE, TX 78660 (NAICS 238910). OSHA activity number 342258944.

Watch Seto Vargas Utilities, INC. — free Get an email when a new federal OSHA severe-injury report for Seto Vargas Utilities, INC. is published. One employer, no account, unsubscribe in one click.
Site address
WEISS LANE / JESSE BOHLS DR.
City
PFLUGERVILLE
State
TX
ZIP
78660
Mailing
5300 NAVARRO CREEK RD., DEL VALLE, TX 78617
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238910
Employees
15
Ownership type
A

3 citations on file for this inspection.

1926.21 B02

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2173.00 · Current $869.00 Reduced
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury:    On or about April 17, 2017, employees were installing a water line in an excavation approximately 80 feet long and 8 feet deep without having all workers trained in recognizing and avoidance of such hazards as, but not limited to electrical shock hazards and the regulations in excavation safety such as, but not limited to cave-in protection and adequate egress.
Recent events (2)
  • — I (O) $869.2
  • — Z (S) $2173

1926.405 G02 IV

Other-than-serious 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2173.00 · Current $869.00 Reduced
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws:    On or about April 17, 2017, the employer was using a portable sump pump to remove the water from the 8 foot deep trench with an extension cord that no longer had strain relief and the cable insulation was pulled away showing the copper wiring, exposing employees to a shock hazard.
Recent events (2)
  • — I (O) $869.2
  • — Z (S) $2173

1926.651 C02

Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2173.00 · Current $869.00 Reduced
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees:    On or about April 17, 2017, employees were working in an excavation approximately 8 feet deep and 80 feet long with only one ladder causing employees to have to travel more than 25 lateral feet to exit the excavation, exposing employees to the hazards of delayed/impeded egress in the event of a cave-in or other emergency.