OSHA Inspection: DOWNING ROOFING, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DOWNING ROOFING, INC. in 7080/7084 REMMINGTON VILLA DR., MARYVILLE, IL 62062 (NAICS 238160). OSHA activity number 342263514.

Watch Downing Roofing, INC. — free Get an email when a new federal OSHA severe-injury report for Downing Roofing, INC. is published. One employer, no account, unsubscribe in one click.
Site address
7080/7084 REMMINGTON VILLA DR.
City
MARYVILLE
State
IL
ZIP
62062
Mailing
126 LOU ROSA, COLLINSVILLE, IL 62234
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
4
Ownership type
A

4 citations on file for this inspection.

1926.20 B01

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $3622.00 · Current $0.00 Reduced
29 CFR 1926.20(b)(1):  The employer did not initiate and maintain accident prevention programs as necessary to comply with this part:    The employer did not initiate and maintain an accident prevention program to establish criteria for protecting employees from fall from heights and struck by hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3622

1926.102 A01

Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $2897.00 · Current $1738.00 Reduced
29 CFR 1926.102(a)(1):  Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents:      Eye protective equipment was not used when employees were exposed to eye injury while removing old roof shingles and using pneumatic nail guns to install new ones.
Recent events (2)
  • — I (S) $1738
  • — Z (S) $2897

1926.152 D04

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $3622.00 · Current $0.00 Reduced
29 CFR 1926.152(d)(4): At least one portable fire extinguisher having a rating of not less than 20B:C units was not provided on all vehicles used for transporting and/or dispensing flammable or combustible liquids:  The employer did not ensure that a portable fire extinguisher was available to employees who were carrying a 5 gallon gasoline can in the vehicle. The gasoline was being used to fill the air compressor.
Recent events (2)
  • — I (S) $0
  • — Z (S) $3622

1926.501 B13

Serious Gravity 10 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $5070.00 · Current $3042.00 Reduced
29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m)  or more above lower levels was not protected by guardrail systems, safety net systems, personal fall arrest systems, or an alternative fall protection measure under another provision of paragraph 1926.501 (b), nor did the employer demonstrate that it is infeasible or creates a greater hazard to use these systems and develop and implement a fall protection plan which meets the requirements of paragraph (k) of section 1926.502:      The employer did not ensure fall protection was implemented during residential construction operations when workers were exposed to the hazard of falling approximately ten (10) feet off the roof eve when they were removing old and installing new roofing shingles.
Recent events (2)
  • — I (S) $3042
  • — Z (S) $5070

View DOWNING ROOFING, INC.'s full OSHA safety record →