Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SERVICE DISABLED CONTRACTING GROUP, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of SERVICE DISABLED CONTRACTING GROUP, INC. in BUILDING 1607, FORT EUSTIS, VA 23604 (NAICS 236220). OSHA activity number 342265691.

Watch Service Disabled Contracting Group, INC. — free Get an email when a new federal OSHA severe-injury report for Service Disabled Contracting Group, INC. is published. One employer, no account, unsubscribe in one click.
Site address
BUILDING 1607
City
FORT EUSTIS
State
VA
ZIP
23604
Mailing
1108 TIDEWATER DR., STE C, NORFOLK, VA 23504
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236220
Employees
40
Ownership type
A

6 citations on file for this inspection.

1926.416 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $6338.00 · Current $6338.00
29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means:  a) Building 1607, Fort Eustis, VA 23604: On or about April 18, 2017, and times prior thereto, subcontractor employees were permitted to perform roofing work and handle materials including (but not limited to) 8' eave trim sections, in proximity to 120/240 volt energized power lines and to wear fall arrest equipment as a means of fall protection while working above the same energized power lines, exposing employees to electrical hazards.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $6338
  • — Z (S) $6338

1926.502 D16 III

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.502(d)(16)(iii): Personal fall arrest systems, when stopping a fall, were not rigged such that an employee could neither free fall more than 6 feet (1.8 m) nor contact any lower level:  a) Building 1607, Fort Eustis, VA 23604: On or about April 18, 2017, and times prior thereto, subcontractor employees that performed roofing work wore personal fall arrest systems that were rigged such that the employees could contact a lower level, including 120/240 volt energized power lines, exposing the employees to fall hazards.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.502 F01 III

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $6338.00 · Current $6338.00
29 CFR 1926.502(f)(1)(iii): Points of access, material handling areas, storage areas, and/or hoisting areas were not connected to the work area by an access path formed by two warning lines:  a) Building 1607, Fort Eustis, VA 23604: On or about April 18, 2017, and times prior thereto, the material handling area(s) were not connected to the work area by an access path formed by two warning lines for subcontractor employees that worked on the roof and that were involved in material handling, exposing the employees to fall hazards.  Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (S) $6338
  • — Z (S) $6338

1926.502 F01 IV

Other-than-serious 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.502(f)(1)(iv): When the path to the point of access was not in use, a rope, wire, chain, or other barricade, equivalent in strength and height to the warning line, was not placed across the path at the point where the path intersected the warning lines erected around the work area:    a) Building 1607, Fort Eustis, VA 23604: On or about April 18, 2017, and times prior thereto, the access path formed by two warning lines at the point where the path intersected the warning lines erected around the work area was not barricaded, exposing the subcontractor employees to fall hazards.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1926.502 F02 II

Other-than-serious 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.502(f)(2)(ii): The rope, wire, or chain was not rigged or supported in such a way that its lowest point (including sag) was not less than 34 inches (0.9 m) from the walking/working surface and its highest point no more than 39 inches (1.0 m) from the walking/working surface:    a) Building 1607, Fort Eustis, VA 23604: On or about April 18, 2017, and times prior thereto, the employer did not rig the warning lines in such a way to prevent warning line sag to low points down to approximately 11" from the roof surface, exposing employees to fall hazards.    Abatement certification required within 10 days after abatement date. The certification shall include a statement that abatement is complete, the date and method of abatement, and state that employees and their representatives were informed of this abatement.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1926.503 B01

Other-than-serious 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.503(b)(1): The employer did not verify compliance with paragraph (a) of this section by preparing a written (training) certification record including the name or other identity of the employee trained, the date(s) of the training, and the signature of the person who conducted the training or the signature of the employer:  a) Building 1607, Fort Eustis, VA 23604: On or about April 18, 2017, and times prior thereto, the employer did not verify compliance with paragraph (a) of this section for each subcontractor employee that performed roofing work at heights up to 28 eave to ground fall distance.  No abatement certification or documentation required.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342265691.