Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: THERMAL PIPE SYSTEMS, INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of THERMAL PIPE SYSTEMS, INC. in 4913 ARMSTRONG RD., DURANT, OK 74702 (NAICS 332996). OSHA activity number 342270352.

Watch Thermal Pipe Systems, INC. — free Get an email when a new federal OSHA severe-injury report for Thermal Pipe Systems, INC. is published. One employer, no account, unsubscribe in one click.
Site address
4913 ARMSTRONG RD.
City
DURANT
State
OK
ZIP
74702
Mailing
P.O. BOX 1725, DURANT, OK 74701
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332996
Employees
15
Ownership type
A

8 citations on file for this inspection.

1910.106 D04 IV

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $3622.00 · Current $1700.00 Reduced
29 CFR 1910.106(d)(4)(iv):  Ventilation. Every inside storage room was not provided with either a gravity or a mechanical exhaust ventilation system.     On or about April 19, 2017 and at times prior thereto, the employer transfers flammable chemicals, from a 55gallon drum to a 5 gallon pail, inside of a room that did not have adequate ventilation installed, exposing employees to inhalation hazards.
Recent events (2)
  • — I (S) $1700
  • — Z (S) $3622

1910.106 E06 II

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.106(e)(6)(ii): Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 degree F (37.8 degree C), were dispensed into containers without the containers being electrically interconnected.    On or about April 19, 2017 and at times prior thereto, the employer did not ensure 55 gallon storage drums with flammable chemicals and the 5 gallon pails used to transfer chemicals were properly grounded, exposing employees to fire and/or explosion hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 L01 I

Serious Gravity 5 2 instances 15 exposed
Issued
Abate by
Penalty
Initial $2897.00 · Current $1400.00 Reduced
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l).    On or about April 19, 2017 and at times prior thereto, the employer did not ensure employees operating a powered industrial truck were trained and evaluated to safely operate the vehicle, exposing employees to struck-by hazards.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2897

1910.305 B01 II

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2897.00 · Current $1400.00 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed.    On or about April 19, 2017 and at times prior thereto, the employer did not ensure all openings within a box were effectively covered, exposing employees to electrical hazards.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2897

1910.305 G01 IV A

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure.    On or about April 19, 2017 and at times prior thereto, the employer installed an electrical extension cord into the crack of the concrete floor and used it as permanent wiring, exposing employees to electrical hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1904.32 A03

Other-than-serious 1 instance 15 exposed
Issued
Abate by
Penalty
Initial $724.00 · Current $300.00 Reduced
29 CFR 1904.32(a)(3): The employer did not certify an OSHA 300A Form or equivalent.    On or about April 19, 2017, the employer failed to certify the annual summary of work-related injuries and illnesses.
Recent events (2)
  • — I (O) $300
  • — Z (O) $724

1910.242 B

Other-than-serious 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.242(b): Effective chip guarding and personal protective equipment was not used when compressed air was used for cleaning purposes.  On or about April 19, 2017 and at times prior thereto, the employer did not ensure the high pressure compressed air wand that employees used for cleaning equipment was reduced to 30 p.s.i., exposing employees to struck-by hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.243 C01

Other-than-serious 1 instance 15 exposed
Issued
Penalty
Initial $406.00 · Current $200.00 Reduced
29 CFR 1910.243(c)(1): Abrasive wheel(s) were used on portable grinder(s) which were not provided with safety guard(s) meeting the requirements specified in 29 CFR 1910.243(c)(1) through (c)(4).    On or about April 19, 2017 and at times prior thereto, the employer did not ensure a guard was provided for an abrasive wheel grinder being used by employees, exposing employees to struck-by hazards.
Recent events (2)
  • — I (O) $200
  • — Z (O) $406

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342270352.