DURANT, OK —
OSHA Inspection: THERMAL PIPE SYSTEMS, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of THERMAL PIPE SYSTEMS, INC. in 4913 ARMSTRONG RD., DURANT, OK 74702 (NAICS 332996). OSHA activity number 342270352.
Where did this inspection happen?
- Establishment
- THERMAL PIPE SYSTEMS, INC.
- Site address
- 4913 ARMSTRONG RD.
- City
- DURANT
- State
- OK
- ZIP
- 74702
- Mailing
- P.O. BOX 1725, DURANT, OK 74701
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332996
- Employees
- 15
- Ownership type
- A
Citations
8 citations on file for this inspection.
1910.106 D04 IV
- Issued
- Abate by
- Penalty
- Initial $3622.00 · Current $1700.00 Reduced
General-duty citation text
29 CFR 1910.106(d)(4)(iv): Ventilation. Every inside storage room was not provided with either a gravity or a mechanical exhaust ventilation system. On or about April 19, 2017 and at times prior thereto, the employer transfers flammable chemicals, from a 55gallon drum to a 5 gallon pail, inside of a room that did not have adequate ventilation installed, exposing employees to inhalation hazards.
Recent events (2)
- — I (S) $1700
- — Z (S) $3622
1910.106 E06 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.106(e)(6)(ii): Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 degree F (37.8 degree C), were dispensed into containers without the containers being electrically interconnected. On or about April 19, 2017 and at times prior thereto, the employer did not ensure 55 gallon storage drums with flammable chemicals and the 5 gallon pails used to transfer chemicals were properly grounded, exposing employees to fire and/or explosion hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 L01 I
- Issued
- Abate by
- Penalty
- Initial $2897.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l). On or about April 19, 2017 and at times prior thereto, the employer did not ensure employees operating a powered industrial truck were trained and evaluated to safely operate the vehicle, exposing employees to struck-by hazards.
Recent events (2)
- — I (S) $1400
- — Z (S) $2897
1910.305 B01 II
- Issued
- Abate by
- Penalty
- Initial $2897.00 · Current $1400.00 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed. On or about April 19, 2017 and at times prior thereto, the employer did not ensure all openings within a box were effectively covered, exposing employees to electrical hazards.
Recent events (2)
- — I (S) $1400
- — Z (S) $2897
1910.305 G01 IV A
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure. On or about April 19, 2017 and at times prior thereto, the employer installed an electrical extension cord into the crack of the concrete floor and used it as permanent wiring, exposing employees to electrical hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1904.32 A03
- Issued
- Abate by
- Penalty
- Initial $724.00 · Current $300.00 Reduced
General-duty citation text
29 CFR 1904.32(a)(3): The employer did not certify an OSHA 300A Form or equivalent. On or about April 19, 2017, the employer failed to certify the annual summary of work-related injuries and illnesses.
Recent events (2)
- — I (O) $300
- — Z (O) $724
1910.242 B
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.242(b): Effective chip guarding and personal protective equipment was not used when compressed air was used for cleaning purposes. On or about April 19, 2017 and at times prior thereto, the employer did not ensure the high pressure compressed air wand that employees used for cleaning equipment was reduced to 30 p.s.i., exposing employees to struck-by hazards.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.243 C01
- Issued
- Penalty
- Initial $406.00 · Current $200.00 Reduced
General-duty citation text
29 CFR 1910.243(c)(1): Abrasive wheel(s) were used on portable grinder(s) which were not provided with safety guard(s) meeting the requirements specified in 29 CFR 1910.243(c)(1) through (c)(4). On or about April 19, 2017 and at times prior thereto, the employer did not ensure a guard was provided for an abrasive wheel grinder being used by employees, exposing employees to struck-by hazards.
Recent events (2)
- — I (O) $200
- — Z (O) $406
More inspections in this industry (NAICS 332996)
ELK POINT, SD—2026-07-07
NEXT MECHANICAL
HARRISON, OH—2026-06-25
ENERFAB MODULAR SHOP
PENNSAUKEN, NJ—2026-06-15
PIONEER PIPE CONTRACTORS, INC.
MEMPHIS, TN—2026-05-28
ISLAND INDUSTRIES, INC.
LEBANON, TN—2026-05-27
FERGUSON ENTERPRISES, LLC
More inspections in OK
MADILL, OK—2026-07-08
MID AMERICAN STEEL & WIRE CO., LLC
SEILING, OK—2026-06-26
GORE ENERGY
ADA, OK—2026-06-25
PAN AMERICA ELECTRIC , INC.
ADA, OK—2026-06-25
CITATION OIL & GAS CORPORATION
EDMOND, OK—2026-06-23
BRICK EXPERTS INC.
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342270352.