Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DON'S GRINDING AND LAPPING SERVICE, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DON'S GRINDING AND LAPPING SERVICE, INC. in 8700 TWEED DR, HOUSTON, TX 77061 (NAICS 332710). OSHA activity number 342274354.

Watch Don'S Grinding AND Lapping Service, INC. — free Get an email when a new federal OSHA severe-injury report for Don'S Grinding AND Lapping Service, INC. is published. One employer, no account, unsubscribe in one click.
Site address
8700 TWEED DR
City
HOUSTON
State
TX
ZIP
77061
Mailing
8700 TWEED DR, HOUSTON, TX 77061
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
33
Ownership type
A

7 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $6338.00 · Current $3169.00 Reduced
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this section:    a)  At building #315, the energy control procedure did not identify all the energy sources of Rotary Grinder #1, model number AGS-2060AHD. Employees perform maintenance tasks on this machine such as, but not limited to,  lubing the machine parts, exposing employees to struck-by, and caught-in between hazards.
Recent events (2)
  • — I (S) $3169
  • — Z (S) $6338

1910.147 C06 I

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard were being followed:  a)  At Building #315, the employer did not conduct periodic inspections of the energy control procedure for Rotary Grinder #1, exposing employees to struck by hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.212 A01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $5070.00 · Current $2535.00 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    a)  At the front entrance to Building #313, a belt sander was not guarded at each nip point where the sanding belt runs onto the pulley and the unused run of the sanding belt was not guarded.
Recent events (2)
  • — I (S) $2535
  • — Z (S) $5070

1910.303 B02

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $5070.00 · Current $2535.00 Reduced
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    a)  At Building #315, a relocatable power tap was not used in accordance with the instructions included in the listing and labeling in that it was attached to a wooden bench, exposing employees to electrical hazards.
Recent events (2)
  • — I (S) $2535
  • — Z (S) $5070

1910.305 B01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $6338.00 · Current $3166.00 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:    a)  At the front entrance to Building #311, an unused opening in an electrical junction box was not closed, exposing employees to electrical hazards.
Recent events (2)
  • — I (S) $3166
  • — Z (S) $6338

1910.334 A02 II

Other-than-serious 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service:    a)  In Building #313, a flexible cord connected to a control pendant was frayed with exposed conductors, exposing employees to electrical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1910.178 L04 III

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $711.00 · Current $355.00 Reduced
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years:    a)  At building #315, employees operating a Caterpillar forklift, model #P5000, serial #AT18C00974, had not received a three year evaluation, exposing employees to fall and struck by hazards.
Recent events (2)
  • — I (O) $355
  • — Z (O) $711

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342274354.