HOUSTON, TX —
OSHA Inspection: DON'S GRINDING AND LAPPING SERVICE, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DON'S GRINDING AND LAPPING SERVICE, INC. in 8700 TWEED DR, HOUSTON, TX 77061 (NAICS 332710). OSHA activity number 342274354.
Where did this inspection happen?
- Establishment
- DON'S GRINDING AND LAPPING SERVICE, INC.
- Site address
- 8700 TWEED DR
- City
- HOUSTON
- State
- TX
- ZIP
- 77061
- Mailing
- 8700 TWEED DR, HOUSTON, TX 77061
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 33
- Ownership type
- A
Citations
7 citations on file for this inspection.
1910.147 C04 II
- Issued
- Abate by
- Penalty
- Initial $6338.00 · Current $3169.00 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this section: a) At building #315, the energy control procedure did not identify all the energy sources of Rotary Grinder #1, model number AGS-2060AHD. Employees perform maintenance tasks on this machine such as, but not limited to, lubing the machine parts, exposing employees to struck-by, and caught-in between hazards.
Recent events (2)
- — I (S) $3169
- — Z (S) $6338
1910.147 C06 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard were being followed: a) At Building #315, the employer did not conduct periodic inspections of the energy control procedure for Rotary Grinder #1, exposing employees to struck by hazards.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Abate by
- Penalty
- Initial $5070.00 · Current $2535.00 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) At the front entrance to Building #313, a belt sander was not guarded at each nip point where the sanding belt runs onto the pulley and the unused run of the sanding belt was not guarded.
Recent events (2)
- — I (S) $2535
- — Z (S) $5070
1910.303 B02
- Issued
- Abate by
- Penalty
- Initial $5070.00 · Current $2535.00 Reduced
General-duty citation text
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) At Building #315, a relocatable power tap was not used in accordance with the instructions included in the listing and labeling in that it was attached to a wooden bench, exposing employees to electrical hazards.
Recent events (2)
- — I (S) $2535
- — Z (S) $5070
1910.305 B01 II
- Issued
- Abate by
- Penalty
- Initial $6338.00 · Current $3166.00 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) At the front entrance to Building #311, an unused opening in an electrical junction box was not closed, exposing employees to electrical hazards.
Recent events (2)
- — I (S) $3166
- — Z (S) $6338
1910.334 A02 II
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service: a) In Building #313, a flexible cord connected to a control pendant was frayed with exposed conductors, exposing employees to electrical hazards.
Recent events (2)
- — I (O) $0
- — Z (S) $0
1910.178 L04 III
- Issued
- Abate by
- Penalty
- Initial $711.00 · Current $355.00 Reduced
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: a) At building #315, employees operating a Caterpillar forklift, model #P5000, serial #AT18C00974, had not received a three year evaluation, exposing employees to fall and struck by hazards.
Recent events (2)
- — I (O) $355
- — Z (O) $711
More inspections in this industry (NAICS 332710)
WIXOM, MI—2026-07-16
MANSON MANUFACTURING LLC DBA TOMCO MANUFACTURING
CLAWSON, MI—2026-07-16
FOUR WAY INDUSTRIES INC
CLAWSON, MI—2026-07-16
FOUR WAY INDUSTRIES INC
CLARKLAKE, MI—2026-07-15
CLARKLAKE MACHINE INC
MUSKEGON HEIGHTS, MI—2026-07-15
L. THOMPSON COMPANY LLC DBA TOTAL QUALITY MACHINING
More inspections in TX
WICHITA FALLS, TX—2026-07-16
UNITED RENTALS, INC.
SAN MARCOS, TX—2026-07-16
CASA MECHANICAL SERVICES, LTD.
CLARKSVILLE, TX—2026-07-15
SEQUOIAS TREE EXPERT LLC
EL PASO, TX—2026-07-15
SURE STEEL
CORPUS CHRISTI, TX—2026-07-15
NORTH STAR ENERGY SOLUTIONS LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342274354.