Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DIRECTORATE OF EMERGENCY SERVICES

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DIRECTORATE OF EMERGENCY SERVICES in 1610 SHARON LANE ROAD BUILDING 1436, FORT BELVOIR, VA 22060 (NAICS 922160). OSHA activity number 342279049.

Watch Directorate OF Emergency Services — free Get an email when a new federal OSHA severe-injury report for Directorate OF Emergency Services is published. One employer, no account, unsubscribe in one click.
Site address
1610 SHARON LANE ROAD BUILDING 1436
City
FORT BELVOIR
State
VA
ZIP
22060
Mailing
6100 ABBOT ROAD, BUILDING 2124, FORT BELVOIR, VA 22060
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
922160
Employees
92
Ownership type
D

2 citations on file for this inspection.

1910.22 B

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.22(b): The employer did not ensure that each walking-working surface can support the maximum intended load for that surface.  a)    Building 1436, Warehouse: On or about 04/17/2017, the mezzanine floor used for storage of various equipment and supplies, the maximum intended floor load was not specified.  Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $0

1910.28 B01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.28(b)(1)(i): The employer did not ensure that each employee on a walking-working surface with an unprotected side or edge that was 4 feet (1.2 m) or more above a lower level was protected from falling by one or more of the following: Guardrail systems, safety net systems, or personal fall arrest systems:  a)    Building 1436: On or about 03/21/2017, an employee accessed a mezzanine to get firefighting gear and was not provided with fall protection, as a result the employee was exposed to an 8.5 feet fall hazard.  Abatement certification required within 10 days after abatement date.  The certification shall include a statement that abatement is complete, date and method of abatement, and states employees and their representatives were informed of this abatement.
Recent events (1)
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342279049.