Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: DESIGNER CRAFT WOODWORKING,INC.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of DESIGNER CRAFT WOODWORKING,INC. in 601 COMMERCE RD., LEXINGTON, NE 68850 (NAICS 337110). OSHA activity number 342279825.

Watch Designer Craft Woodworking,Inc. — free Get an email when a new federal OSHA severe-injury report for Designer Craft Woodworking,Inc. is published. One employer, no account, unsubscribe in one click.
Site address
601 COMMERCE RD.
City
LEXINGTON
State
NE
ZIP
68850
Mailing
601 COMMERCE RD., LEXINGTON, NE 68850
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
337110
Employees
15
Ownership type
A

6 citations on file for this inspection.

1910.28 B11 II

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2173.00 · Current $1000.00 Reduced
29 CFR 1910.28(b)(11)(ii):     Each flight of stairs having at least 3 treads and at least 4 risers was not equipped with stair rail systems and handrails in accordance with Table D-2, Stairway Handrail Requirements:      The employer is failing to protect employees from fall hazards when ascending and descending the stairs used to access the break room.  This was most recently documented at 601 Commerce Rd. Lexington, Nebraska ,on or about April 26,2017.  Employees are utilizing an enclosed set of stairs that lead to the break room.  This set of stairs was not equipped with a hand rail, in accordance with this subpart.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2173

1910.106 D04 I

Serious Gravity 5 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $3622.00 · Current $2500.00 Reduced
29 CFR 1910.106(d)(4)(i):     Opening(s) from inside flammable and combustible storage room(s) were not provided with approved self-closing fire doors. The inside flammable and combustible storage room(s) were not liquid-tight where the walls joined the floor:    The employer is failing to ensure that employees are protected from a potential fire hazard.  This was most recently documented at 601 Commerce Rd. Lexington Nebraska on or about April 26, 2017.  The flammable storage area door was not self-closing or constructed in such a manner as to make the room liquid tight (walls joined the floor).
Recent events (2)
  • — I (S) $2500
  • — Z (S) $3622

1910.106 D04 IV

Serious Gravity 5 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.106(d)(4)(iv):     Every inside storage room was not provided with either a gravity or a mechanical exhaust ventilation system that provides for a complete change of air within the room at least six times per hour.      The employer is failing to protect employees from fire and explosion hazards.  This was most recently documented at 601 Commence Rd. Lexington, Nebraska on or about April 26, 2017.  The flammable storage room was not equipped with a ventilation system.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 E01

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3622.00 · Current $2500.00 Reduced
29 CFR 1910.134(e)(1):     The employer will provide a medical evaluation to determine the employee's ability to use a respirator.     The employer is failing to ensure that employee(s) are not exposing to health hazards associated with wearing tight fitting respirators prior to being medically evaluated.  This was most recently documented  at 601 Commerce Rd. Lexington, Nebraska on or about April 26, 2017.  The employer failed to medical evaluate an employee prior to wearing a tight fitting respirator.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $3622

1910.242 B

Serious Gravity 5 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $2897.00 · Current $1000.00 Reduced
29 CFR 1910.242(b):     Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:    The employer is failing to ensure that employees are not exposed to eye injuries and air embolism. This was most recently documented at 601 Commerce Rd. Lexington, Nebraska on or about April 26, 2017 when employees are using compressed air for cleaning purposes at a pressure greater than 30 p.s.i.  The house air pressure on the compressor gauge showed 106 p.s.i.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2897

1910.307 C

Serious Gravity 5 2 instances 10 exposed
Issued
Abate by
Penalty
Initial $3622.00 · Current $2500.00 Reduced
29 CFR 1910.307(c): Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location:      a. The employer is failing to protect employees from a fire and explosion hazard.  This was most recently documented at 601 Commerce Rd. Lexington Nebraska on or about April 26, 2017. The room lighting used to illuminate the flammable storage area was not of the Class and Division required for this area.     b. The employer is failing to protect employees from a fire and explosion hazard.  This was most recently documented at 601 Commerce Rd. Lexington Nebraska on or about April 26, 2017. The electrical outlets behind the Rover A3 CNC router were not of a class and type appropriate for a potentially flammable dust area.
Recent events (2)
  • — I (S) $2500
  • — Z (S) $3622

View DESIGNER CRAFT WOODWORKING,INC.'s full OSHA safety record →