BUFFALO, NY —
OSHA Inspection: EAST COAST ORTHOTIC & PROSTHETIC CORP.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of EAST COAST ORTHOTIC & PROSTHETIC CORP. in 505 DELAWARE AVENUE, BUFFALO, NY 14202 (NAICS 339113). OSHA activity number 342285491.
Where did this inspection happen?
- Establishment
- EAST COAST ORTHOTIC & PROSTHETIC CORP.
- Site address
- 505 DELAWARE AVENUE
- City
- BUFFALO
- State
- NY
- ZIP
- 14202
- Mailing
- 505 DELAWARE AVENUE, BUFFALO, NY 14202
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 339113
- Employees
- 10
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.219 C04 I
- Issued
- Abate by
- Penalty
- Initial $4155.00 · Current $2500.00 Reduced
General-duty citation text
29 CFR 1910.219(c)(4)(i): Shaft ends projecting more than one-half the diameter of the shaft were not guarded by nonrotating caps or safety sleeves. a) On or about 4/28/17, in the Grinding Room, employees were exposed to being caught on the 6 inch unprotected rotating shaft when operating the S-400 sander to sand smooth the edges of orthotics and prosthetics. a) On or about 4/28/17, in the Grinding Room, employees were exposed to being caught on the 2.25 inch unprotected rotating shaft when operating the S-400 sander to sand smooth the edges of orthotics and prosthetics. ABATEMEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2500
- — Z (S) $4155
1910.242 B
- Issued
- Abate by
- Penalty
- Initial $5541.00 · Current $3500.00 Reduced
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a) On or about 4/28/17, grinding room, employees are exposed to flying debris when using airlines for drying the black bins with compressed air pressure of up to 95 p.s.i. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $3500
- — Z (S) $5541
1910.303 G02 I
- Issued
- Abate by
- Penalty
- Initial $4155.00 · Current $2500.00 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets or other forms of approved enclosures, or other means listed under this provision: a) On or about 4/28/17, in the Compressor Room, employees were exposed to fire and electrical hazards when entering the compressor room due to the switch at the entrance of the room having live electrical wiring exposed. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2500
- — Z (S) $4155
More inspections in this industry (NAICS 339113)
MT JULIET, TN—2026-05-21
HOLLISTER INCORPORATED
CHICO, CA—2026-05-14
RESCUE 42, INC
NEWPORT, VT—2026-04-21
GALVION BALLISTICS LTD.
JACKSONVILLE, FL—2026-03-26
INVOTEC INTERNATIONAL INC
TAMPA, FL—2026-03-26
STEMRAD
More inspections in NY
MAYVILLE, NY—2026-07-16
MAYVILLE VILLAGE DPW
NEW HYDE PARK, NY—2026-07-16
NORTH HEMPSTEAD TN MICHAEL J TULLY PARK
CONESUS, NY—2026-07-16
CONESUS TN HIGHWAY DEPT
COMSTOCK, NY—2026-07-15
NYSDOCCS WASHINGTON CORRECTIONAL FACILITY
BALDWINSVILLE, NY—2026-07-15
LYSANDER TOWN HIGHWAY DEPARTMENT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342285491.