Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: EAST COAST ORTHOTIC & PROSTHETIC CORP.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of EAST COAST ORTHOTIC & PROSTHETIC CORP. in 505 DELAWARE AVENUE, BUFFALO, NY 14202 (NAICS 339113). OSHA activity number 342285491.

Watch East Coast Orthotic & Prosthetic Corp. — free Get an email when a new federal OSHA severe-injury report for East Coast Orthotic & Prosthetic Corp. is published. One employer, no account, unsubscribe in one click.
Site address
505 DELAWARE AVENUE
City
BUFFALO
State
NY
ZIP
14202
Mailing
505 DELAWARE AVENUE, BUFFALO, NY 14202
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
339113
Employees
10
Ownership type
A

3 citations on file for this inspection.

1910.219 C04 I

Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $4155.00 · Current $2500.00 Reduced
29 CFR 1910.219(c)(4)(i): Shaft ends projecting more than one-half the diameter of the shaft were not guarded by nonrotating caps or safety sleeves.    a) On or about 4/28/17, in the Grinding Room, employees were exposed to being caught on the 6 inch unprotected rotating shaft when operating the S-400 sander to sand smooth the edges of orthotics and prosthetics.    a) On or about 4/28/17, in the Grinding Room, employees were exposed to being caught on the 2.25 inch unprotected rotating shaft when operating the S-400 sander to sand smooth the edges of orthotics and prosthetics.    ABATEMEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $2500
  • — Z (S) $4155

1910.242 B

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $5541.00 · Current $3500.00 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:    a) On or about 4/28/17, grinding room, employees are exposed to flying debris when using airlines for drying the black bins with compressed air pressure of up to 95 p.s.i.      ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $3500
  • — Z (S) $5541

1910.303 G02 I

Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $4155.00 · Current $2500.00 Reduced
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets or other forms of approved enclosures, or other means listed under this provision:    a) On or about 4/28/17, in the Compressor Room, employees were exposed to fire and electrical hazards when entering the compressor room due to the switch at the entrance of the room having live electrical wiring exposed.    ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $2500
  • — Z (S) $4155

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342285491.