Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: TOP ROOFING AND CONST, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of TOP ROOFING AND CONST, LLC in 10200 PARK MEADOWS DR. BLDG 26, LONE TREE, CO 80124 (NAICS 238160). OSHA activity number 342290848.

Watch TOP Roofing AND Const, LLC — free Get an email when a new federal OSHA severe-injury report for TOP Roofing AND Const, LLC is published. One employer, no account, unsubscribe in one click.
Site address
10200 PARK MEADOWS DR. BLDG 26
City
LONE TREE
State
CO
ZIP
80124
Mailing
7961 ONEIDA ST., COMMERCE CITY, CO 80022
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
2
Ownership type
A

2 citations on file for this inspection.

1926.20 B02

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1630.00 · Current $1630.00
29 CFR 1926.20(b)(2): The employer did not initiate and maintain a safety program which provides for frequent and regular inspections of jobsites, materials, and equipment to be made by a competent person:    (a)  On or about April 27, 2017, Top Roofing and Const., as the controlling employer, did not ensure that the employees of Francisco Fuentes, subcontractor, were safe from health and safety hazards by conducting effective regular and frequent safety inspections of the job site by a competent person, and ensuring hazards were identified and mitigated such as, but not limited to, fall hazards.    Abatement Note: Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
  • — Z (S) $1630

1926.1053 B01

Serious Gravity 1 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $1630.00 · Current $1630.00
29 CFR 1926.1053(b)(1): Where (a) portable ladder(s) was/were used for access to an upper level landing surface and the ladder's length did not allow the ladder side rails to extend at least 3 feet (0.9 m) above the upper landing surface being accessed, the ladder was not secured at its top to a rigid support that will not deflect, and/or a grasping device was not provided to assist employees in mounting and dismounting the ladder.    (a)  On or about April 27, 2017, the employer did not ensure employees safely used the ladder to gain access to the residential roof.  The ladder was not secured at the top and did not extend three feet above the landing surface.      Abatement Note:  Abatement certification is required for this item (see enclosed "Certification of Corrective Action Worksheet").
Recent events (1)
  • — Z (S) $1630

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342290848.