SEYMOUR JOHNSON AFB, NC —
OSHA Inspection: WILLIAM REMODELING & HOME IMPROVEMENT, INC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of WILLIAM REMODELING & HOME IMPROVEMENT, INC in 268 SQUIER AVENUE, SEYMOUR JOHNSON AFB, NC 27531 (NAICS 238310). OSHA activity number 342291077.
Where did this inspection happen?
- Establishment
- WILLIAM REMODELING & HOME IMPROVEMENT, INC
- Site address
- 268 SQUIER AVENUE
- City
- SEYMOUR JOHNSON AFB
- State
- NC
- ZIP
- 27531
- Mailing
- 506 MILLS RD, GOLDSBORO, NC 27534
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238310
- Employees
- 9
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 E01
- Issued
- Penalty
- Initial $2173.00 · Current $0.00 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. Seymour Johnson AFB, Community Center: Employees had no means of safe access and egress working from a frame scaffolding.
Recent events (2)
- — I (S) $0
- — Z (S) $2173
1926.451 G04 I
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(g)(4)(i): Guardrail systems were not installed along all open sides and ends of platforms before being released for use by employees other than erection/dismantling crews: Seymour Johnson AFB Community Center: On or before May 2, 2017, an employee was working from a fabricated frame scaffold 12 feet high, and did not have the guardrails installed.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 G04 II
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(g)(4)(vii): Each toprail or equivalent member of a guardrail system was not capable of withstanding, without failure, a force applied in any downward or horizontal direction at any point along its top edge of at least 100 pounds (445 n) or guardrail systems installed on single-point adjustable suspension scaffolds or two-point adjustable suspension scaffolds, and at least 200 pounds (890 n) for guardrail systems installed on all other scaffolds. Seymour Johnson AFB Community Center: Scaffold guardrail system was not adequately secured with a double wrap wire connection. Single wrap wire tensile strength did not provide support for 200 lbs in any outward or downward direction. Wire connections were not twisted to a minimum of 5 wraps to ensure the ultimate strength.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.20 B02
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s) Seymour Johnson, Community Center: Employer did not ensure that safety and health hazards were being identified and corrected in a timely manner.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.454 A
- Issued
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. Seymour Johnson AFB, Community Center: The employer did not develop and implement a training program for employees on the recognition, evaluation, and control of hazards associated with scaffolding operations.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 238310)
BANNOCKBURN, IL—2026-07-16
BUILDER SERVICES GROUP, INC. DBA CJ INSULATION
NAMPA, ID—2026-07-15
INTERIOR SYSTEMS, INC.
BRIDGEPORT, WV—2026-07-14
EASLEY & RIVERS, INC.
ELLETTSVILLE, IN—2026-07-13
ENVIRO HEAT, LLC
ELLETTSVILLE, IN—2026-07-13
RWS INSULATION SERVICES, LLC
More inspections in NC
KERNERSVILLE, NC—2026-07-15
161552 - EDC, INC.
FRANKLINTON, NC—2026-07-15
161551 - LINDSAY PRECAST, LLC
RALEIGH, NC—2026-07-14
161550 - SUNRISE SENIOR LIVING MANAGEMENT, INC.
LAURINBURG, NC—2026-07-14
161549 - AMERICAN WOOD FIBERS, INC.
RURAL HALL, NC—2026-07-14
161546 - CAVERT WIRE COMPANY, LLC
Source