OSHA Inspection: JIM'S ROOFING SERVICE & SON, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JIM'S ROOFING SERVICE & SON, LLC in E4120 RUNWAY DR, WAUPACA, WI 54981 (NAICS 238160). OSHA activity number 342301710.

Watch Jim'S Roofing Service & SON, LLC — free Get an email when a new federal OSHA severe-injury report for Jim'S Roofing Service & SON, LLC is published. One employer, no account, unsubscribe in one click.
Site address
E4120 RUNWAY DR
City
WAUPACA
State
WI
ZIP
54981
Mailing
E470 GOLKE ROAD, WAUPACA, WI 54981
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
3
Ownership type
A

5 citations on file for this inspection.

1926.20 B02

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3259.00 · Current $2281.00 Reduced
29 CFR 1926.20(b)(2): It shall be the responsibility of the employer to initiate and maintain programs as may be necessary to comply with accident prevention; such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.  a)  On May 4, 2017 at E4120 Runway Drive in Waupaca, the employer did not conduct adequate safety inspections prior to employees working on barn soffit from scaffold at 10.5 ft. above surface level.  No fall protection equipment installed, work platform not fully decked and positioned greater than 14 in. from face of barn wall, and base plates used as foundation on grassy surface.
Recent events (2)
  • — I (S) $2281.3
  • — Z (S) $3259

1926.451 B01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2173.00 · Current $1521.00 Reduced
29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).  a)  On May 4, 2017 at E4120 Runway Drive in Waupaca, employees were working from one 20 ft. Long scaffold plank supported by frame scaffold at 10.5 ft. above surface level without the platform fully decked between the scaffold uprights.
Recent events (2)
  • — I (S) $1521.1
  • — Z (S) $2173

1926.451 B03

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(b)(3): Except as provided in paragraphs (b)(3)(i) and (ii) of this section, the front edge of all platforms shall not be more than 14 inches (36 cm) from the face of the work, unless guardrail systems are erected along the front edge and/or personal fall arrest systems are used in accordance with paragraph (g) of this section to protect employees from falling.  a)  On May 4, 2017 at E4120 Runway Drive in Waupaca, employees were installing soffit on a barn eave from a scaffold plank at 10.5 ft. above surface level with the plank edge positioned 17 in. from the face of the barn wall.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 C02

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.  a)  On May 4, 2017 at E4120 Runway Drive in Waupaca, employees were working from a platform supported by frame scaffold at 10.5 ft. above surface level on a grassy surface without mud sills installed under the base plates.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 G01 VII

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(g)(1)(vii): For all scaffolds not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, each employee shall be protected by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.  a)  On May 4, 2017 at E4120 Runway Drive in Waupaca, employees were working from one 20 ft. Long stage plank supported by frame scaffold at 10.5 ft. above surface level without utilizing any fall protection equipment.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0