Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: SOUTH COAST GAS COMPANY, INC.

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of SOUTH COAST GAS COMPANY, INC. in 709 E. MAIN ST., LOCKPORT, LA 70374 (NAICS 238220). OSHA activity number 342302486.

Watch South Coast GAS Company, INC. — free Get an email when a new federal OSHA severe-injury report for South Coast GAS Company, INC. is published. One employer, no account, unsubscribe in one click.
Site address
709 E. MAIN ST.
City
LOCKPORT
State
LA
ZIP
70374
Mailing
4076 HWY 1, RACELAND, LA 70394
Inspection type
Federal Agency (M)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
30
Ownership type
A

3 citations on file for this inspection.

1910.132 D01

Serious Gravity 10 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $8873.00 · Current $6211.00 Reduced
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment.     On or about May 04, 2017, At 709 East Main St., Lockport, LA, the employer did not effectively determine proper protective equipment (PPE) for employees working in areas where electrical and overhead hazards were present.  Employee(s) worked near hazards including, but not limited to, damaged overhead electrical power lines, low hanging energized power lines, broken wooden electrical poles, and transformers without wearing adequate PPE.
Recent events (2)
  • — I (S) $6211.1
  • — Z (S) $8873

1910.212 A03 II

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $5070.00 · Current $2535.00 Reduced
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s):      On or about May 05, 2017, in the repair shop at South Coast Gas Company; the employer did not provide a guard at the point of operation for the JET Equipment & Tools drill press (Model No. JDP-17MF; S/N 4047005).
Recent events (2)
  • — I (S) $2535
  • — Z (S) $5070

1910.333 A

Serious Gravity 10 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $8873.00 · Current $6211.00 Reduced
29 CFR 1910.333(a): Safety-related work practices were not employed to prevent electric shock or other injuries resulting from either direct or indirect electrical contacts, when work was performed near or on equipment or circuits which were or could be energized:    On or about May 04, 2017, At 709 East Main St., Lockport, LA, the employer did not develop or implement safe work practices to protect employee(s) from contact with energized electrical power lines.
Recent events (2)
  • — I (S) $6211.1
  • — Z (S) $8873

OXYCHEM

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342302486.