1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: THE CHEMOURS COMPANY

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of THE CHEMOURS COMPANY in 8480 DUPONT ROAD, WASHINGTON, WV 26181 (NAICS 325188). OSHA activity number 342311560.

Watch THE Chemours Company — free Get an email when a new federal OSHA severe-injury report for THE Chemours Company is published. One employer, no account, unsubscribe in one click.
Site address
8480 DUPONT ROAD
City
WASHINGTON
State
WV
ZIP
26181
Mailing
P.O. BOX 1217, WASHINGTON, WV 26181
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325188
Employees
650
Ownership type
A

2 citations on file for this inspection.

1910.147 D06

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $9054.00 · Current $6791.00 Reduced
29 CFR 1910.147(d)(6): Prior to starting work on machines or equipment that had been locked out or tagged out, the authorized employee did not verify that isolation and deenergization of the machine or equipment had been accomplished:    (a)  On May 5, 2017, prior to starting work on the Monomer Unit, High Roof to remove the 1054 FT1 flow transmitter, the authorized employee did not verify that isolation and deenergization of a process line containing perfluoroisobutene and tetrafluoroethylene dimer had been accomplished.
Recent events (3)
  • — F (O) $6790.5
  • — C (S) $9054
  • — Z (S) $9054

1910.134 A02

Deleted Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $9054.00 · Current $0.00 Reduced
29 CFR 1910.134(a)(2): A respirator was not provided by the employer to each employee when such equipment was necessary to protect the health of the employee  (a)  Monomer Unit, High Roof:  On May 5, 2017, the employer did not ensure that employees used the provided respiratory protection while opening a process line containing perfluoroisobutene and tetrafluoroethylene dimer during the removal of the 1054 FT1 flow transmitter.
Recent events (3)
  • — F (S) $0
  • — C (S) $9054
  • — Z (S) $9054

View THE CHEMOURS COMPANY's full OSHA safety record →