Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: SOUTH TEXAS OUTFITTERS MANAGEMENT CORPORATION

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of SOUTH TEXAS OUTFITTERS MANAGEMENT CORPORATION in 8211 HWY 281 NORTH, SAN ANTONIO, TX 78216 (NAICS 811111). OSHA activity number 342315322.

Watch South Texas Outfitters Management Corporation — free Get an email when a new federal OSHA severe-injury report for South Texas Outfitters Management Corporation is published. One employer, no account, unsubscribe in one click.
Site address
8211 HWY 281 NORTH
City
SAN ANTONIO
State
TX
ZIP
78216
Mailing
8211 HWY 281 NORTH, SAN ANTONIO, TX 78216
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811111
Employees
16
Ownership type
A

5 citations on file for this inspection.

1910.134 I05 III

Serious Gravity 5 2 instances 2 exposed
Issued
Abate by
Penalty
Initial $2897.00 · Current $1159.00 Reduced
29 CFR 1910.134(i)(5)(iii): The compressor's sorbent bed and filters were not maintained and replaced or refurbished periodically as instructed by the manufacturer:    (a) Bedliner Application Area: On or about May 10, 2017, employee(s) who use supplied air respirators were exposed to inhalation hazards from the use of a Clemco CPF Air Filter which was not maintained or replaced per the manufacturer's specifications.     (b) Abrasive Blasting Booth, Rear: On or about May 10, 2017, employee(s) who use supplied air respirators were exposed to inhalation hazards from the use of a Clemco CPF Air Filter which was not maintained or replaced per the manufacturer's specifications.
Recent events (2)
  • — I (S) $1158.8
  • — Z (S) $2897

1910.134 I05 IV

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(i)(5)(iv): The tag containing the most recent change to the sorbent beds was not kept or maintained at the compressor:  Abrasive Blasting Booth: On or about May 10, 2017, employees who use supplied air respirators were exposed to inhalation hazards from the use of CPF filters which had not been maintained or changed per the manufacturer's specifications, and a tag with the last filter change date was not available.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.134 I07

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3622.00 · Current $1449.00 Reduced

Hazardous substances 0560

29 CFR 1910.134(i)(7): Oil lubricated compressor(s) used to supply breathing air did not have a high-temperature or carbon monoxide alarm(s) or both:      Facility: On or about May 10, 2017, employee(s) were exposed to inhalation hazards from the use of supplied air respirators with an oil-lubricated Ingersoll-Rand Rotary Screw Air Compressor (Model R37ie), and neither a carbon monoxide alarm nor carbon monoxide monitoring procedures were in use.
Recent events (2)
  • — I (S) $1448.8
  • — Z (S) $3622

1910.134 G01 I A

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(g)(1)(i)(A): Respirators with tight-fitting facepieces were worn by employees who had facial hair that came between the sealing surface of the facepiece and the face or that interfered with valve function:  Bedliner Application Area: On or about May 10, 2017, the employer did not ensure that employee(s) who were required to wear tight-fitting, half-mask respirators while performing bedliner application tasks were free of facial hair between the sealing surface of the facepiece and the face to protect employees from chemical inhalation hazards.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.334 A02 II

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service:  Abrasive Blasting Booth: On or about May 10, 2017, employee(s) were exposed to electrical hazards from a flexible extension cord that had visible damage to the cord sheath, was missing strain relief at the female end, and was kept in service.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0