Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: BURLINGTON GRAPHIC SYSTEMS, INC.

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of BURLINGTON GRAPHIC SYSTEMS, INC. in 2600 CHICORY ROAD, RACINE, WI 53403 (NAICS 323110). OSHA activity number 342317906.

Watch Burlington Graphic Systems, INC. — free Get an email when a new federal OSHA severe-injury report for Burlington Graphic Systems, INC. is published. One employer, no account, unsubscribe in one click.
Site address
2600 CHICORY ROAD
City
RACINE
State
WI
ZIP
53403
Mailing
2600 CHICORY ROAD, RACINE, WI 53403
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
323110
Employees
189
Ownership type
A

8 citations on file for this inspection.

1910.147 D02

Serious Gravity 10 2 instances 6 exposed
Issued
Abate by
Penalty
Initial $11408.00 · Current $8000.00 Reduced
29 CFR 1910.147(d)(2): Machine or equipment shutdown. The machine or equipment shall be turned off or shut down using the procedures established for the machine or equipment. An orderly shutdown must be utilized to avoid any additional or increased hazard(s) to employees as a result of the equipment stoppage.    (a) Chicago Die Cutting Press 770: On or about May 10, 2017 the mechanical press was not turned off or shut down using the procedures established for the press prior to the press operator setting a die.  This exposed the press operator to crushing hazards and amputation injury.
Recent events (2)
  • — I (S) $8000
  • — Z (S) $11408

1910.147 D03

Serious Gravity 5 2 instances 6 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(d)(3): All energy isolating devices that were needed to control the energy to the machine or equipment were not physically located and operated in such a manner as to isolate the machine or equipment from the energy source(s):  (a) Chicago Die Cutting Press 770: On or about May 10, 2017, gravitational energy was not isolated by placing die safety blocks between the upper and lower die when performing die setting and removal. This exposed the press operator to crushing hazard and amputation injury.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 D04 I

Serious Gravity 5 2 instances 6 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees:  (a) Chicago Die Cutting Press 770: On or about May 10, 2017, lockout or tagout devices had not been affixed to each energy source of the press by the authorized employees prior to engaging in die removal and die setting process.  This exposed the press operator to crushing hazard and amputation injury.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.217 D09 I

Serious Gravity 5 2 instances 6 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.217(d)(9)(i): The employer did not establish a die setting procedure for mechanical power press(es) that would ensure compliance with 29 CFR 1910.217(c).  (a) Die setting procedures were not developed by the company for mechanical power press operators to utilize when setting, adjusting or removing dies.  This exposed press operators to crushing hazards and amputation injury.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.217 D09 IV

Serious Gravity 5 2 instances 6 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.217(d)(9)(iv): Safety blocks were not used when mechanical power press die(s) were being adjusted or repaired in the press:  (a) Chicago Die Cutting Press 770: On or about May 10, 2017, the press operator was conducting a die setting and adjustment process.  Die safety blocks were not utilized, exposing the press operator to crushing hazards and amputation injury.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.217 C01

Serious Gravity 5 2 instances 6 exposed
Issued
Abate by
Penalty
Initial $6926.00 · Current $3500.00 Reduced
29 CFR 1910.217(c)(1): The employer did not provide and insure the usage of "point of operation guards" or properly applied and adjusted point of operation devices on every operation performed on a mechanical power press according to Table O-10:    (a) Chicago Die Cutting Press 770: The press did not have all points of operation guarded on the sides of the press. This exposed press operators to crushing hazards and amputation injury.    (b) Chicago Die Cutting Press 771: The press did not have all points of operation guarded on the sides of the press. This exposed press operators to crushing hazards and amputation injury.
Recent events (2)
  • — I (S) $3500
  • — Z (S) $6926

1910.178 Q07

Other-than-serious 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.178(q)(7): Industrial trucks shall be examined before being placed in service, and shall not be placed in service if the examination shows any condition adversely affecting the safety of the vehicle. Such examination shall be made at least daily. Where industrial trucks are used on a round-the-clock basis, they shall be examined after each shift. Defects when found shall be immediately reported.  (a) The propane forklift(s) and electric Standup forklift(s) used for material handling operations throughout the manufacturing and warehouse areas of this facility were not consistently examined before being placed into daily service.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G01 III

Other-than-serious 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(1)(ii)(I): 29 CFR 1910.305(g)(1)(iii): When used as permitted in paragraph (g)(1)(ii)(I) of this section, the flexible cord was not equipped with an attachment plug that would be energized from an approved receptacle outlet.  (a) In the warehouse, a 24 volt battery charger, bolted onto a pallet was connected/direct wired with a flexible cable to the side of a 3 phase 480 volt AC breaker switch box.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View BURLINGTON GRAPHIC SYSTEMS, INC.'s full OSHA safety record →