Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of DEXTER MAGNETIC TECHNOLOGIES, INC. in 1050 MORSE AVE., ELK GROVE VILLAGE, IL 60007 (NAICS 332999). OSHA activity number 342333689.

Watch Dexter Magnetic Technologies, INC. — free Get an email when a new federal OSHA severe-injury report for Dexter Magnetic Technologies, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1050 MORSE AVE.
City
ELK GROVE VILLAGE
State
IL
ZIP
60007
Mailing
1050 MORSE AVE., ELK GROVE VILLAGE, IL 60007
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332999
Employees
115
Ownership type
A

4 citations on file for this inspection.

1910.147 C04 II

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $6519.00 · Current $3900.00 Reduced
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(A), (c)(4)(ii)(B), (c)(4)(ii)(C) and (c)(4)(ii)(D):    (a) Throughout the facility - Energy control procedures utilized when maintaining and servicing machines and equipment were inadequate and did not fully address the scope, purpose, authorization, rules, the means to enforce compliance and the types and magnitudes of hazardous energy.  During the period between May 1, 2017 and June 22, 2017, employee(s) were exposed to potentially hazardous energy sources when performing service and/or maintenance on machines in the workplace, including the Mazak milling machine.     In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (3)
  • — F (S) $3900
  • — C (S) $6519
  • — Z (S) $6519

1910.147 C07 I

Serious Gravity 1 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $4889.00 · Current $7800.00
29 CFR 1910.147(c)(7)(i): The employer did not provide adequate training to ensure that employees acquired the knowledge and skills required for the safe application, usage and removal of energy control devices:    (a) Grinding Department - Employees in the Grinding Department perform servicing activities to the grinders, including replacing the grinding wheels on the surface grinder, without locking and tagging out the equipment. On or about May 15, 2017, an employee performed a service activity on a surface grinder while setting up the machine for a new job. The machine was not locked and/or tagged out at the time of the service activity.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (3)
  • — F (S) $7800
  • — C (S) $4889
  • — Z (S) $4889

1910.147 D

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $8149.00 · Current $0.00 Reduced
29 CFR 1910.147(d): The established procedure for the application of energy control (the lockout or tagout procedures) did not cover the actions listed in and was not done in sequence as required by 29 CFR 1910.147(d)(1)-(6):    (a) In areas including the Grinding Department -  On or about May 15, 2017, a worker changed the grinding wheel on a surface grinder and failed to implement energy control application steps as the machine was only shut down using the control circuitry (on/off switch) and not deenergized to perform the servicing work [per the 1910.147(d)(2) requirements]. As a result, the remaining applicable energy control elements, involving machine isolation [(d)(3)], LOTO device application [(d)(4)], dissipation of residual energy [(d)(5)(i)], and verification of isolation [(d)(6)], were not implemented to protect employees from machine servicing hazards.    In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (3)
  • — F (S) $0
  • — C (S) $8149
  • — Z (S) $8149

1910.147 C06 I

Other-than-serious 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(6)(i): The employer did not conduct an annual or more frequent inspection of the energy control procedure to ensure that the procedure and requirements of this standard were followed:  (a) Throughout the facility - The employer did not ensure the annual evaluation of the energy control procedure(s) was completed.  During the period between May 1, 2017 and June 22, 2017, employee(s) were exposed to potentially hazardous energy sources when performing service and/or maintenance on machines in the workplace, including the Mazak milling machine, when utilizing procedures that had not been properly inspected.   In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).