Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JM WELDING INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of JM WELDING INC. in 916 LAMOKIN STREET, CHESTER, PA 19013 (NAICS 332323). OSHA activity number 342340494.

Watch JM Welding INC. — free Get an email when a new federal OSHA severe-injury report for JM Welding INC. is published. One employer, no account, unsubscribe in one click.
Establishment
JM WELDING INC.
Site address
916 LAMOKIN STREET
City
CHESTER
State
PA
ZIP
19013
Mailing
916 LAMOKIN STREET, CHESTER, PA 19013
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332323
Employees
10
Ownership type
A

9 citations on file for this inspection.

1910.36 D01

Serious Gravity 5 2 instances 1 exposed
Issued
Abate by
Penalty
Initial $2173.00 · Current $1630.00 Reduced
29 CFR 1910.36(d)(1): Employees must be able to open an exit route door from the inside at all times without keys, tools, or special knowledge. A device such as a panic bar that locks only from the outside is permitted on exit discharge doors.    a) Near the loading dock at the rear of the facility on the South side of the building: The exit door located in the equipment storage area was locked preventing safe egress in the event of an emergency; thus exposing employees to fire hazards.    b) Near the loading dock at the rear of the facility on the North side of the building.: The exit door from the painting area was locked preventing safe egress in the event of an emergency; thus exposing employees to fire hazards.      This condition was observed 17 MAY 2017.
Recent events (2)
  • — I (S) $1629.75
  • — Z (S) $2173

1910.37 A03

Serious Gravity 1 1 instance 4 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.37(a)(3): Exits routes were not maintained to provide free and unobstructed access.  a) Near the loading dock at the rear of the facility on the South side of the building.: The route to the exit door was blocked by paint barrels, pallets, wires, and metal beams preventing safe egress in the event of an emergency; thus exposing employees to fire hazards.  b)a) Near the loading dock at the rear of the facility on the North side of the building.: The route to the exit door was blocked by metal pipes preventing safe egress in the event of an emergency; thus exposing employees to fire hazards.  Condition observed on/about 17 May 2017.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.179 J03

Serious Gravity 1 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $1630.00 · Current $1223.00 Reduced
29 CFR 1910.179(j)(3): Periodic inspection. Complete inspections of the crane shall be performed at intervals as generally defined in paragraph (j)(1)(ii)(b) of this section, depending upon its activity, severity of service, and environment, or as specifically indicated below. These inspections shall include the requirements of paragraph (j)(2) of this section and in addition, the following items. Any deficiencies such as listed shall be carefully examined and determination made as to whether they constitute a safety hazard:    1) Facility, In the shop on the east side of the building: The employer did not ensure that the Yale chain hoist was inspected periodically thus exposing employees to struck by hazards.     Condition noted/observed on/about 17 MAY 2017.
Recent events (2)
  • — I (S) $1222.5
  • — Z (S) $1630

1910.179 J02 III

Serious Gravity 5 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.179(j)(2)(iii): A certification record which includes the date of inspection, the signature of the person who performed the inspection and the serial number, or other identifier, of the hook inspected, was not maintained:  1) Facility, In the shop on the east side of the building: The employer did not ensure that the Yale chain hoist hook was inspected monthly thus exposing employees to struck by hazards.   Condition observed on/about 17 MAY 2017.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.179 J02 IV

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.179(j)(2)(iv): Hoist chains, including end connections, for excessive wear, twist, distorted links interfering with proper function, or stretch beyond manufacturer's recommendations. Visual inspection daily; monthly inspection with a certification record which includes the date of inspection, the signature of the person who performed the inspection and an identifier of the chain which was inspected.  1) Facility, In the shop on the east side of the building: The employer did not ensure that the Yale hoist chains were inspected monthly thus exposing employees to struck by hazards.   Condition observed on/about 17 MAY 2017.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.215 B09

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2717.00 · Current $2038.00 Reduced
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one-fourth inch.    a) In the facility: The employer did not ensure that the tongue guard on all bench grinders were set to a maximum opening of one-fourth inch exposing employees to struck by hazards.    This condition was observed on or about 17 MAY 2017.
Recent events (2)
  • — I (S) $2037.75
  • — Z (S) $2717

1910.253 B04 III

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2717.00 · Current $2038.00 Reduced
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage shall be separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:    a) Facility exterior adjacent to the back wall of the building: Employees are exposed to fire and explosion hazards in that the employer does not ensure that oxygen cylinders in storage are separated from fuel-gas cylinders such as:  -acetylene  -propane    This condition observed on/about 17 MAY 2017.
Recent events (2)
  • — I (S) $2037.75
  • — Z (S) $2717

1910.134 C02 I

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(c)(2)(i): An employer may provide respirators at the request of employees or permit employees to use their own respirators, if the employer determines that such respirator use will not in itself create a hazard. If the employer determines that any voluntary respirator use is permissible, the employer shall provide the respirator users with the information contained in Appendix D to this section.  1) Jobsite: The Employer did not provide employees, voluntarily wearing the Miller LPR-100 half-face respirator, with the information contained in Appendix D of this section ("Information for Employees Using Respirators When Not Required Under the Standard").   Condition noted on/about 17 May 2017.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134 C02 II

Other-than-serious 1 instance 10 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.134(c)(2)(ii): In addition, the employer must establish and implement those elements of a written respiratory protection program necessary to ensure that any employee using a respirator voluntarily is medically able to use that respirator, and that the respirator is cleaned, stored, and maintained so that its use does not present a health hazard to the user. Exception: Employers are not required to include in a written respiratory protection program those employees whose only use of respirators involves the voluntary use of filtering facepieces (dust masks).  a) The employee did not ensure that employees voluntarily using the Miller LPR-100 half-face respirator were medically able to use that respirator and that the respirator is clean, stored and maintained so that it does not present a health hazard to the user.   This condition observed/noted on or about 17 MAY 2017.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342340494.