2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: TORTILLERIA GALLO DE ORO LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of TORTILLERIA GALLO DE ORO LLC in 1302 LAKE AVE, LAKE WORTH, FL 33460 (NAICS 311830). OSHA activity number 342344900.

Watch Tortilleria Gallo DE ORO LLC — free Get an email when a new federal OSHA severe-injury report for Tortilleria Gallo DE ORO LLC is published. One employer, no account, unsubscribe in one click.
Site address
1302 LAKE AVE
City
LAKE WORTH
State
FL
ZIP
33460
Mailing
1302 LAKE AVE, LAKE WORTH, FL 33460
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311830
Employees
4
Ownership type
A

3 citations on file for this inspection.

1910.212 A05

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $2309.00 · Current $1385.00 Reduced
29 CFR 1910.212(a)(5): Fan blade guard(s) were not provided where the periphery of the blades was less than seven feet from the floor or working level:   On or about 5/23/2017, at the storage room of the above addressed worksite, employees were exposed to a caught by hazard while working in the proximity of a fan that lacked a guard.
Recent events (2)
  • — I (S) $1385.4
  • — Z (S) $2309

1910.263 E01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Penalty
Initial $1847.00 · Current $1108.00 Reduced
29 CFR 1910.263(e)(1)(i): Mixers with external power application shall have all belts, chains, gears, pulleys, sprockets, clutches, and other moving parts completely enclosed:  On or about 5/23/2017, at the production area, employees were exposed to a caught by hazard while preparing tortilla dough with a mixer that lacked a guard on its drive mechanism.
Recent events (2)
  • — I (S) $1108.2
  • — Z (S) $1847

1910.305 B02 I

Other-than-serious 1 instance 2 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(2)(i): Pull boxes, junction boxes, and fittings were not provided with covers approved for the purpose:     On or about 5/23/2017, at the production area of the above addressed worksite, a toggle switch installed within a junction box lacked a cover plate, exposing employees to an electrical hazard.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342344900.