Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: THE ZELCO GROUP, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of THE ZELCO GROUP, LLC in 100 LAUREL STREET, WEST HAVEN, CT 06516 (NAICS 236118). OSHA activity number 342354784.

Watch THE Zelco Group, LLC — free Get an email when a new federal OSHA severe-injury report for THE Zelco Group, LLC is published. One employer, no account, unsubscribe in one click.
Site address
100 LAUREL STREET
City
WEST HAVEN
State
CT
ZIP
06516
Mailing
109 JONES S STREET, WEST HAVEN, CT 06516
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236118
Employees
9
Ownership type
A

7 citations on file for this inspection.

1926.451 F03

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2716.00 · Current $1850.00 Reduced
29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity:    Jobsite: The pump jack scaffold from that the employees were working was not inspected daily for visible defects by a competent person.
Recent events (2)
  • — I (S) $1850
  • — Z (S) $2716

1926.451 F06

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6).Note:  Specify distances as indicated in table in paragraph (f)(6) of this section.  Jobsite: The pump jack scaffold from that the employees were working was erected and used within 4 feet of exposed and energized power lines.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 F07

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2716.00 · Current $1850.00 Reduced
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person.    Jobsite:  The pump jack scaffold from that the employees were working was not erected under the supervision of a competent person in scaffold erection.
Recent events (2)
  • — I (S) $1850
  • — Z (S) $2716

1926.451 G01 VII

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2716.00 · Current $1850.00 Reduced
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section.    Jobsite:  The employees who were working from the pump jack scaffold were not protected from fall hazards by the use of guardrails or personal fall arrest systems.
Recent events (2)
  • — I (S) $1850
  • — Z (S) $2716

1926.501 B13

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b):   Jobsite:  The employee who was engaged in residential construction activities on the porch roof was not protected from fall hazards by the use guardrails, safety nets or personal fall arrest systems.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.454 A01

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $2173.00 · Current $1450.00 Reduced
29 CFR 1926.454(a)(1): The employer failed to have each employee who performs work while on a scaffold trained regarding the nature of any electrical hazards, fall hazards and falling object hazards in the work area.    Jobsite:  The employer did not ensure that the employees who were working from the pump jack scaffold were trained to recognize the hazards associated with the type of scaffold being used.
Recent events (2)
  • — I (S) $1450
  • — Z (S) $2173

1926.454 B01

Serious Gravity 5 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.454(b)(1): The employer did not have each employee who is involved in erecting, disassembling, moving, operating, maintaining, or inspecting a scaffold trained by a competent person to recognize the hazards associated with the work in question.  Jobsite: The employees that were involved in erecting, maintaining and inspecting the pump jack scaffold were not trained by a competent person to recognize any hazards associated with the work in question.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0