Safety Incidents OSHA Severe Injury Reports · 2015–2025
4,113,118Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: JIN MINGXUE

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JIN MINGXUE in 6746 PRINTERS BLVD. BUILDING 8, NEW ALBANY, OH 43054 (NAICS 238170). OSHA activity number 342375763.

Watch JIN Mingxue — free Get an email when a new federal OSHA severe-injury report for JIN Mingxue is published. One employer, no account, unsubscribe in one click.
Establishment
JIN MINGXUE
Site address
6746 PRINTERS BLVD. BUILDING 8
City
NEW ALBANY
State
OH
ZIP
43054
Mailing
5545 ROCKWOOD COURT, COLUMBUS, OH 43229
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238170
Employees
4
Ownership type
A

3 citations on file for this inspection.

1926.501 B13

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $3803.00 · Current $1902.00 Reduced
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502.  a. On or about June 6, 2017, located at Building 8 in New Albany, Ohio, employees were installing siding on a steep-slope roof without any means of fall protection, thereby exposing the employees to a fall of approximately 14 feet.
Recent events (2)
  • — I (S) $1901.5
  • — Z (S) $3803

1926.1053 B01

Serious Gravity 5 1 instance 3 exposed
Issued
Abate by
Penalty
Initial $2173.00 · Current $1087.00 Reduced
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.  a. On or about June 6, 2017, located at Building B in New Albany, Ohio, employees used an extension ladder to gain access to and from the roof of the apartment building while the ladder did not extend at least three feet about the landing surface, thereby exposing the employees to a maximum fall hazard of 10 feet.
Recent events (2)
  • — I (S) $1086.5
  • — Z (S) $2173

1926.1053 B04

Serious Gravity 5 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $2716.00 · Current $1358.00 Reduced
29 CFR 1926.1053(b)(4): Ladders shall be used only for the purpose for which they were designed.  a. On or about June 6, 2017, located at Building B in New Albany, Ohio, employees used a Werner six foot stepladder in order to gain access from the roof of a porch to the roof of the apartment while the ladder was in the closed position and leaning against the apartment which was against the way the ladder was designed by the manufacturer, thereby exposing the employees to 6 foot or 10 foot fall.
Recent events (2)
  • — I (S) $1358
  • — Z (S) $2716

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 342375763.