Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PEROXYCHEM TONAWANDA PLANT

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of PEROXYCHEM TONAWANDA PLANT in 35 SAWYER AVENUE, TONAWANDA, NY 14150 (NAICS 325180). OSHA activity number 342413408.

Watch Peroxychem Tonawanda Plant — free Get an email when a new federal OSHA severe-injury report for Peroxychem Tonawanda Plant is published. One employer, no account, unsubscribe in one click.
Site address
35 SAWYER AVENUE
City
TONAWANDA
State
NY
ZIP
14150
Mailing
35 SAWYER AVENUE, TONAWANDA, NY 14150
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
325180
Employees
91
Ownership type
A

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 2 exposed
Issued
Abate by
Penalty
Initial $12675.00 · Current $8500.00 Reduced
OSH ACT of 1970 Section (5)(a)(1):     The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees
Recent events (3)
  • — J (S) $8500
  • — C (S) $12675
  • — Z (S) $12675

1910.269 M03 II

Deleted Serious Gravity 10 1 instance 2 exposed
Issued
Penalty
Initial $12675.00 · Current $0.00 Reduced
29 CFR 1910.269(m)(3)(ii): The employer did not ensure that all switches, disconnectors, jumpers, taps, and other means through which known sources of electric energy may be supplied to the particular lines and equipment to be denenergized were open.  The employer did not render such means inoperable, unless its design does not so permit, and then sure that such means are tagged to indicate that employees are at work:  a) On or about 05/18/17 at the PeroxyChem substation located at 78 Sawyer Avenue, Tonawanda, New York; employees were performing preventative maintenance on the breakers in the substation. While preparing to work on breaker #6, an employee contacted live equipment and suffered burns and fractures. Switch #10 was left closed causing a backfeed from breaker #2 to breaker #6.  NO ABATEMENT CERTIFICATION REQUIRED
Recent events (3)
  • — J (S) $0
  • — C (S) $12675
  • — Z (S) $12675