1,224,460Inspections Most recent open 2026-07-13 Last loaded 2026-07-16
Safety Incidents OSHA Severe Injury Reports · 2015–2025

OSHA Inspection: WILLIAMS EXCAVATING, INC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of WILLIAMS EXCAVATING, INC in WYOTA STREET & AMELIA, CASSVILLE, WI 53806 (NAICS 237110). OSHA activity number 342433059.

Watch Williams Excavating, INC — free Get an email when a new federal OSHA severe-injury report for Williams Excavating, INC is published. One employer, no account, unsubscribe in one click.
Site address
WYOTA STREET & AMELIA
City
CASSVILLE
State
WI
ZIP
53806
Mailing
18750 US RT. 20, EAST DUBUQUE, IL 61025
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
237110
Employees
3
Ownership type
A

4 citations on file for this inspection.

1926.100 A

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2173.00 · Current $1087.00 Reduced
29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:    On or about June 27, 2017, an employee working in a trench approximately 10.5 feet deep was exposed to overhead struck-by hazards.  The employee was not wearing a hard hat/protective helmet.     Abatement certification is required for this item in accordance with 1903.19(c).
Recent events (2)
  • — I (S) $1087
  • — Z (S) $2173

1926.651 C02

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2173.00 · Current $1086.00 Reduced
29 CFR 1926.651(c)(2): Means of egress from trench excavations. A stairway, ladder, ramp or other safe means of egress shall be located in trench excavations that are 4 feet (1.22 m) or more in depth so as to require no more than 25 feet (7.62 m) of lateral travel for employees.    On or about June 27, 2017, an employee working in a trench approximately 10.5 feet deep was not provided with a safe means of access/egress.      Abatement certification required for this item in accordance with 1903.19(c).
Recent events (2)
  • — I (S) $1086
  • — Z (S) $2173

1926.651 H01

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1630.00 · Current $0.00 Reduced
29 CFR 1926.651(h)(1): Employees were working in excavations in which there was accumulated water, or excavations in which water was accumulating, and adequate precautions had not been taken to protect employees against the hazards posed by water accumulation.    On or about June 27, 2017, an employee was working in a trench approximately 10.5 feet deep that had water accumulation.  Measures were not in place to prevent water from accumulating in the trench.      Abatement certification is required for this item in accordance with 1903.19(c).
Recent events (2)
  • — I (O) $0
  • — Z (S) $1630

1926.652 A01

Serious Gravity 10 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $3803.00 · Current $1902.00 Reduced
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c).    On or about June 27, 2017, an employee working in a trench approximately 10.5 feet deep was exposed to potential cave-in hazards.  An adequate cave-in protection system was not utilized.      Abatement documentation is required for this item in accordance with 29 CFR 1903.19(d).
Recent events (2)
  • — I (S) $1902
  • — Z (S) $3803

View WILLIAMS EXCAVATING, INC's full OSHA safety record →